Service tech. information, A. troubleshooting – Kenmore 625.38816 User Manual
Page 21
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
J J-JJ.JJ JJ J-JJ J-i J-J-i-J JJ-kJJJJ-
SECTION 5
^-ij jj
J-JJ J J vJ J J-IJ J J
JJ|^4J4
jj j jj jj
jj«(j_ij jjaj
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) computer has a self
diagnostic function for the electrical system, except
for input power and water meter. The computer
monitors electronic components
and circuits for correct opera
tion. If a malfunction occurs, an
error code appears in the face
plate display.
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SELECT but
ton. SELECT remains operational so the service per
son can make the MANUAL INITIATED ELEC
TRONIC DIAGNOSTICS (below) to further isolate
the defect, and check the water meter.
CODE
POSSIBLE DEFECT
MOST LIKELY
LESS LIKELY
Erri, ЕггЗ,
Err4
motor inoperative / wiring harness or connection to switch / position switch / valve defect causing
high torque ________________ ____________________________________________________________
Errs
faceplate timer (PWA)
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:
1. Unplug transformer from outlet 2. Correct
defect 3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL INITIATED ELECTRONICS
DIAGNOSTICS
To enter diagnostics, press the SELECT button
until 000 - - shows in the display.
TURBINE SWITCHES
nnn _ _
uuu
WATER METER
(A)
~1
SWITCH (B)
A. The first 3 digits indicate water meter operation
as follows:
000 (steady) = Soft water not in use, and no
flow through the meter.
MOTOR
POSITION
SWITCH
VALVE
OUTLET
SENSOR
HOUSING
TURBINE
TURBINE
SUPPORT AND
SHAFT
—OPEN A NEARBY SOFT WATER FAUCET-
000 to 199 (continual) = Repeats display for each
gallon of water passing through the meter.
If you don't get a reading in the display, with faucet
open, pull the sensor from the valve outlet port.
Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.
B.
The letter (P) and dash (or dashes) indicate
POSITION switch operation. If the letter ap
pears, the switch is closed. If the dash shows, the
switch is open.
Use the ON/OFF-HOLD (Recharge Now) but
ton to manually advance the valve into each
cycle and check correct switch operation.
5 - 2
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line