Installing LP Gas Fuel Gauge Assembly
Figure 10a
1. Unscrew the M18x1.5 and M8x1.25 nuts from
the Pressure Cylinder.
2. Unscrew and remove the Fixing Ring from the
Dial. See Fig. 10a.
3. Insert the end with Pressure Cylinder through
the notched hole on right Side Shelf. See
Fig. 10b. Turn the Dial until it matches the
notched hole, and push it into the hole.
4. Screw the Fixing Ring back to the Dial from
the Pressure Cylinder side. See Fig. 10c.
5. Insert the Pressure Cylinder into Pressure
Cylinder Guide, and secure using the de
tached M18x1.5 nut. See Fig. 11.
6. Attach Tank Hook to the lower thread of
Pressure Cylinder, and secure firmly using the
detached M8x1.25 nut. Once tank is con
nected, the dial will indicate amount of gas
in tank.
Natural Gas Safety Instructions
Figure 10b
Your natural gas grill is designed to operate on
natural gas only, at a pressure of 7" water column
(W.C.) (1/4 psig or 1.75 kpa), regulated at the
residential meter. Check with your gas utility
company for local gas pressure and with your local
municipalityfor building code requirements. If your
residential gas line pressure has not been regu
lated to 7" W.C., contact your local gas utility
company for professional assistance.
It is recommended that a Shutoff Val ve be installed at
thegassupplysourceoutdoors. Installata pointafter
the gas pipe exits the outside wall and before the
quick-disconnecthose, or install itatthe point before
the gas line piping enters the ground.
Pipe sealing compound or pipe thread tape
resistant to the action of natural gas must be used
on all male pipe threads when making the
connection.
Disconnect your gas grill from fuel source when
the gas supply is being tested at high pressures.
This gas grill and its individual shutoff valve must
be disconnected from the gas supply pipe system
during any pressure testing of that system at
pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is
being tested at low pressures. The grill must be
isolated from the gas supply pipe system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply pipe
system at pressures equal to or less than 1/2 psi
(3.5kpa).
Figure 10c
Figure 11