Install single bypass valve (coni.), Install holding clips, Figure 8 – Kenmore 625.3835 User Manual
Page 8: Alternate bypass valve installation, Assemble inlet and outlet plumbing, Figure 9, Nstallatìon, Figure 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
nstallatìon
INSTALL SINGLE BYPASS VALVE (coni.)
Before installing the bypass valve and/or installation
adaptors, make sure that the turbine and support are
firmly in place inside the softener valve’s outlet port.
Turbine
Support
Valve Outlet
Turbine
Figure 7
INSTALL HOLDING CLIPS
Bypass Valve or
Plastic Clip
into groove in
bypass or adaptor
Figure 8
ALTERNATE BYPASS VALVE INSTALLATION
If connecting to floor
level plumbing, install
the bypass valve turned
downward, as shown.
ASSEMBLE INLET AND OUTLET PLUMBING
Measure, cut (thread if needed) and put together all
pipe and fittings up to the main water pipe. Make sure
that the incoming water supply pipe goes to the valve
inlet side.
CAUTION: Never solder fittings while connected to
nonmetallic parts. Wait until soldered pipe
has cooled before connection. See Fig. 10.
CAUTION: Be careful when putting pipe fittings togeth
er. Do not cross thread, and do not over
tighten.
4. Solder.
NOTE: To be certain
that heat will not
travel down the pipe
and into the bypass
valve or installation
adaptors, wrap the
bottom of the pipe
and the bypass valve
with a wet rag.
Incoming
Hard
Water
1. Cut pipe to
correct length
Solder. When
cool, do step 3.
Put threaded
adaptor
into
bypass valve
port.
Figure 10
Figure 9