Install grounding clamp, Install covers, Connect to electrical power – Kenmore 625.3835 User Manual
Page 11: Restart the water heater, Nstallation
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
nstallation
INSTALL GROUNDING CLAMP
The house cold water pipe (iron or copper) is often used
to ground all electrical outlets in the home. To maintain
this ground, use the ground clamp kit included in the
parts bag. Install the ground clamp across the inlet
and outlet metal pipes (see Fig. 14). Make sure good
contact is made between the pipe and the clamps.
INSTALL COVERS
After installing your water softener, put the covers on.
Angle the covers so the top cover clips onto the back
first, then bring down in front and clip on the tabs
inside the rim and lower the salt lid closed (See Fig. 5).
CONNECT TO ELECTRICAL POWER
The softener works on 24 volt, 60 FIz electrical power.
The included transformer changes standard 120 volt AC
house power to 24 volts. You must plug the water soft
ener’s transformer into a grounded, 120 volt outlet only.
Be sure the outlet is always “live” so it cannot be
switched off by mistake.
NOTE:
The electrical outlet you plug the transformer
into must be indoors, protected from weather.
METAL PIPE GROUNDING
RESTART THE WATER HEATER
Turn on the gas (or electric) supply to the water heater
and light the pilot.
YOUR PLUMBING INSTALLATION AND
ELECTRICAL WORK ARE NOW COMPLETE.
11