SECTION 5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
CORRECT
SWITCH
DISPLAYS
VALVE CYCLE STATUS
—
Valve in service, fill, brining,
backwash or fast rinse position
„ p
Valve rotating from one position
to another
While in this diagnostic screen^ the following in
formation is available and may be beneficial for
various reasons. This information is retained by
the computer from the first time electrical power
is applied to the face plate.
-- Press 0 to display the number of days this
face plate has had electrical power applied.
- - Press 0 to display the number of regenera
tions initiated by this face plate since the SR code
number was entered.
Press and hold the SELECT button until...
SR17
shows.
CODE
5R I
This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on incorrect programming. Do the follow
ing as needed.
Return the present time display
LECT button.
Press the SE-
To change SR number — Press the UP or DOWN
button until the correct SR code shows. Then, press
the SELECT button and reset the timer...page 1-3.
TIMER PWA REPLACEMENT; Be sure the
valve is in service position when replacing the
timer PWA (observe valve cycle indicator).
If, after installing and programming the re
placement timer PWA, the valve is not in ser
vice position, do the following to assure correct
cycle orientation, or timing, between the face
plate and valve.
Use the MANUAL ADVANCE procedures,
page 5-4. With the RECHARGE button, ad
vance through the recharge cycles until the
valve stops in service position, and RE
CHARGE no longer flashes in the display.
NOTE; The valve motor may automatically
drive through several valve positions while
searching for service. If an error code occurs,
unplug the transformer, then plug in again.
5 - 3
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line