SECTION 5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) computer has a self
diagnostic function for the electrical system, except
for input power and water meter. The computer
monitors electronic components
and circuits for correct opera
tion. If a malfunction occurs, an
error code appears in the face
plate display.
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SELECT but
ton. SELECT remains operational so the service per
son can make the MANUAL INITIATED ELEC
TRONIC DIAGNOSTICS (below) to further isolate
the defect, and check the water meter.
COÖE
POSSIBLE DEFECT
MOST LIKELY
LESS LIKELY
Erri, ЕггЗ,
Err4
motor inoperative / wiring harness or connection to switch / position switch / vaive defect causing
high torque
Err5
faceplate timer (PWA)
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:
1. Unplug transformer from outlet 2. Correct
defect 3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL INITIATED ELECTRONICS
DIAGNOSTICS
To enter diagnostics, press the SELECT button
until 000 - - shows in the display.
TURBINE SWITCHES
nnn __
1Л1Ли
WATER METER (A)
------ 1
SWITCH (B)
A. The first 3 digits indicate water meter operation
as follows:
000 (steady) = Soft water not in use, and no
flow through the meter.
POSITION
SWITCH
VALVE
OUTLET
SENSOR
HOUSING
TURBINE
TURBINE
SUPPORT AND
SHAFT
—OPEN A NEARBY SOFT WATER FAUCET-
000 to 199 (continual) = Repeats display for each
gallon of water passing through the meter.
If you don't get a reading in the display, with faucet
open, puh the sensor from the valve outlet port.
Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.
B. The letter (P) and dash (or dashes) indicate
POSITION switch operation. If the letter ap
pears, the switch is closed. If the dash shows, the
switch is open.
Use the RECHARGE button to manually ad
vance the valve into each cycle and check correct
switch operation.
5 - 2
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line