COUNTERFLOW FURNACE INSTALLATION

For installation of your humidifier on a counterflow

furnace, see Fig. 6. Connect the humidifier to the
supply air plenum using Remote Installation Kit,
Sears Stock No. 9372.

COUNTERFLOW FURNACE INSTALLATION

SUPPLY AIR PLENUM

(Wider Than Stiffener)

GRAVITY FURNACE INSTALLATION

The humidifier works well on gravity furnaces because
of its self-contained blower system. Use the Remote

Installation Kit, Sears Stock No. 9372. The humidifier

must be at least 6" away from the plenum, due to the
higher operating temperature of the furnace.

NOTE: Furnace temperatures above 250°F may
cause failure of fiberglass parts.

Fiber Plenum Ducts

NOTE: The mounting screws supplied are for standard
installation on sheet metal plenum ducts.

If you have fiber plenum ducts, install the plenum

stiffener and components with thru-bolts, nuts, and
washers (not supplied), if necessary, reinforce the
humidifier mounting area on fiber ducts with sheet
metal and provide additional bracing as required to
support the weight of the humidifier and water. (This
fiber duct installation hardware is not supplied and
must be purchased from you local hardware store.)

You may also consider using the remote mount instal­
lation if you have fiber ducts. Purchase the Remote

Installation Kit separately from Sears, Stock No. 9372.

1. The Plenum Stiffener is mounted on the supply

air plenum. Mark a level line at least 2" above the
top of the furnace on the selected surface, if
front service method (Fig. 2) is used. If the
humidifier is to be serviced from the bottom (Fig.
3), mark a level line at least iVb' above the top of
the furnace. Hold stiffener against the plenum
with the bottom edge on a level line and bent
edge flanges towards you. Using a pencil, mark
the location of all holes except hole “A” on

plenum (Fig. 7).

2" to service from front (Fig. 2)
ZVA to service from bottom (Fig. 3)

Fig. 7

If plenum is

narrower

than

stiffener:

The stiffener can be mounted on a plenum as narrow
as 13V2". The stiffener sides will extend past the

plenum (Fig 8). Begin installation as follows:

• New mounting holes will have to be drilled.

Drill the new holes only as far from the edge

as necessary. Use a 1/8" drill bit.

• Mark outline of rectangle as shown in Fig 8.

• Cut out this area of supply air plenum. If edges

are rough, file them smooth.

• Proceed to step 6.

SUPPLY AIR PLENUM

(Narrower Than Stiffener)

Plenum

Stiffener

Fig. 8