SAFETY INSTRUCTION
J
RULES FOR SAFE INSTALLATION & OPERATION
Read these rules and the instructions carefully. Failure to follow the rules and instructions could cause bodily injury
and/or property damage.
• Check your local building codes and utility standards. The installation must comply with their rules.
• Ground the humidifier to prevent electric shock.
• Follow a regular service and maintenance schedule.
• Always shut off electricity and water to humidifier before servicing.
• When the furnace blower is used for air conditioning, the humidifier switch should be turned “OFF.”
• Never oil any part of the humidifier.
• The humidifier must not be installed in an area where freezing is possible.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury. It may also be used to alert, against unsafe practices.
BEFORE YOU STA
KENMORE 3000 PRODUCT FEATURES:
® Self contained 120V 18 gallon model
• Designed for homes up to 3000 sq. ft.
• Works with Heat Pumps
• Quick electric and water disconnect
• Slide-out reservoir and media wheel
with reusable liner
• Substantial water savings - no drain required
• Automatic water feed
• Convenient ON/OFF switch
ACCESSORIES AND ATTACHMENTS
These accessories and attachments can be purchased
at Sears or by contacting Sears Parts: 1-800-366-7278
or online at
• Reservoir Liner (Part No. 215682-01)
• Remote installation Kit (Sears Stock No. 9372)
• Replacement Media Pad (Sears Stock No. 42-9336)
• Sears All-Purpose Humidifier Cleaner (Sears Stock
No. 42-14713)
TOOLS AND MATERIALS NEEDED
Safety glasses
Straight edge ruler
Pencil or grease pencil
Hand drill or grounded electric drill
Drill bits, 5/32", 1/8"
Tin snips or metal cutting saw
Screwdriver (flat point and phillips, medium size)
File
Level
Hammer
Small adjustable wrench
Center punch
Electrical wiring supplies (120V) as needed and of
the type required by local codes.
Materials needed for an alternate installation, use
remote mounting kit, Sears Stock No. 9372 (see
Typical Remote Installations, Page 5).
L
J
CARTON CONTENTS
<» Central Humidifier 3000
® Hardware Package
- Screw (7): Fastens Plenum Stiffener to the
Supply Air Plenum
-
Conduit Connectors (6): Connects wires
together during wiring steps
-
Brass inserts (2): Regulates water flow
-
Brass Compression Sleeve (1): Aids in
connection of plastic tubing to the Quick
Disconnect Socket
-
Capped Fastener: Secures upper case to
Plenum Stiffener
• Saddle Valve Package
- Saddle Valve
-
Brass Compression Sleeve
-
Brass Compression Nut
-
Brass Insert
-
Rubber Gasket
- Screws (2)
-
Nuts (2)
• Humidistat (Humidity Control) Package
-
Humidistat
-
Gasket
-
Mounting Screws (2)
- Operating Instructions
- Wiring Diagram
1/4" Plastic Tubing (10 ft.)
Float
Float Arm
Quick Disconnect Socket
Plenum Stiffener
Maintenance Label
Owner’s Manual
DO-IT-YOURSELF CHECK LIST
If you feel the following operations are within your
skills, you should have no difficulty installing this
humidifier.
® Cutting and drilling sheet metal.
• Using hand tools: screwdriver, wrench, etc.
• Hooking up line voltage electrical connections.