12. Connect the quick disconnect socket to the
plug on the valve body (Fig. 24).
Sleeve
10. Remove the quick disconnect socket, brass
compression nut, and brass sleeve from hardware
bag (Fig. 23). With water supply tubing cut to the
proper length, slide the brass compression nut
and sleeve over the tubing as described in Step
5, Page 10. Slip the brass insert, into the end of
the tubing.
11. Insert the tubing end into the quick disconnect
socket as far as it will go and hold it there. Thread
the brass compression nut onto the quick dis
connect socket, then tighten using two wrenches,
one to hold quick disconnect socket and one to
tighten nut. Do not over-tighten nut (Fig. 23).
To connect, pull back sleeve, push socket onto
plug, release sleeve.
To disconnect, pull back sleeve, unlocking quick
disconnect and sealing water supply line, separate
from the plug.
13. It is best to install an overflow line. Local
building codes may require it. The overflow hole
is in the bottom left front corner of the reservoir
(Fig. 20). Use 1/2" inner diameter rubber or plas
tic tubing to connect to drain. (Tubing not sup
plied. Purchase at your local hardware store.)