SECTION 5
SERVICE TECH. INFORMATION
6A.
TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank Fill, brine draw, regeneration flow
rates, and other controller functions. Always make
the ifiitial checks, and the manual initiated
diagnostics.
NOTE:
The face plate display must show a steady
time fnot flashing).
1. Press the ON/OFF-HOLD button and
hold in for
3 seconds.
RECHARGE NOW begins to flash as
the softener enters tlie fill cycle of regeneration
Remove the brinewell cover and, using a
flashlight, observe fill water entering the tank.
A. If it does not enter the tank, look for an ob
structed nozzle, venturi, fill flow plug, brine tub
ing, or brine valve riser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt storage tank)
0.3 (1.1 liters)
BRINING
\
.16 (.6 liters)
BRINE RINSE
I
.11 (.4 liters)
BACKWASH 1
1.8 (6.8 liters)
FAST RINSE )
1.8 (6.8 liters)
2. After observing fill, press the ON/OFF-HOLD
button to move the softener into brining. A slow
flow of water to the drain will begin. Verify brine
draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable
drop in the liquid level
NOTE:
Be sure a salt bridge is not preventing water
with salt contact
A. If the softener does not draw brine:
- nozzle and/or venturi dirty or defective.
- nozzle and venturi not seated properly on gas
ket.
- restricted drain (check drain fitting and hose).
- defective nozzle and venturi seal.
- other inner valve defect (rotor seal, rotor &
disc, wave washer, etc)
NOTE:
If water system pressure is low, an elevated
drain hose may cause back pressure, stopping brine
draw
3. Again press ON/OFF-HOLD to move the soften
er into backwash. Look for a fast flow of water
from the drain hose.
A. An obstructed flow indicates a plugged top dis
tributor, backwash flow plug, or drain hose.
4. Press ON/OFF-HOLD to move the softener into
fast rinse. Again look for a fast drain flow. Allow
the softener to rinse for a few minutes to flush out
any brine that may remain in the resin tank from
the brining cycle test
5.
To return the softener to service, press ON/OFF-
HOLD.
22