Kenmore 625.34847 User Manual
Page 21
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
SECTION 5
SERVICE TECH. INFORMATION
5Â.
TROUBLESHOOTING
CORRECT
SWITCH
DISPLAYS
VALVE CYCLE STATUS
—
Valve in service, fill, brining, back
wash or fast rinse position
-_ pj
Valve rotating from one position to
another
While in this diagnostic screen, the following in
formation is available and may be beneficial for
various reasons, This information is retained by
the computer from the first time electrical power
is applied to the face plate
—' Press
0
to display the number of days this
face plate has had electrical power applied,
— Press Q to display the number of regenera
tions initiated by this face plate since the SR code
number was entered.
2. Press the
button and hold 3 seconds un
til.,.
SR 22 shows.
CODE
IpirjBig
This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on incorrect programming. Do the following
as needed.
Return the present time display: Press
SELECT button.
the
Change the
SR
number: To display the correct SR
number, press theQUP or DOWN Q burton. Press
SELECT, and
resei the timer.
NOTE:
If the face plate is left in a diagnostic display (or a flashing
display when setting times or hardness), present time
automatically returns if a button is not pressed within 4
minutes.
FACE
plate
; REPLACEMENT: Be sure the valve is in
service position (observe valve cycle indicator)
when replacing the face plate.
If, after installing and programming the replacement face
plate, the valve is not in service position, do the follow
ing to assure correct cycle orientation, or timing, be
tween the face plate and valve
Use the MANUAL ADVANCE procedures, page 22, With
the RECHARGE NOW button, advance through the re
charge cycles until the valve stops in service position,
and RECHARGE no longer flashes in the timer,
NOTE; The valve motor may autamatically drive through
several valve positions while searching for service If an
enot code occurs, unplug the transformer, then plug in
21