SECTION 5
SERVICE TECH. INFORMATION
5Â.
TROUBLESHOOTING
Keep this mainjal with yoiir water softener. If repairs are needed, the service technician must have
the information on the following pages. For telephone assistance, call toll free, 1-800-426-9345,
display
UP button
Sæs Water Iffîs
f o r C m l o m e r A s s i s l m c e
!-8i3iWiS-fl34S
0№QFF.
statARseTCMSKr
ON/OFF-HOID button
(Recharge TonIght-Now)
7
Demand Water Softener
SELECT button
r~
DOWN
button
ALWAYS MAKE THESE
INITIAL
CHECKS FIRST
1. Does the time display show the cotrect time of day?
-
If display is blank, check power soutce to the
softener.
“ If time is flashing, power was off for over 6 hours, The
softener resumes normal operation but regenerations
occur at the wrong time
- If an error code (Example: Err 03) shows in the face
place display, go
lo Automatic Electronic Diagnostics.
Z.
Plumbing bypass valve(s) must be In Full Service
position
3* The inlet and outlet pipes must connect to the softener
valve inlet and outlet respectively
4. Is the transformer plugged into a “live", grounded wail
outlet, and is the power cable fastened securely?
5. The valve drain hose must be free of kinks and sharp
bends, and not elevated over 8 ft above the floor
REMOVE THE TOP COVER AND SALT TANK COVER
6. Is there salt in the storage tank?
7. is the brine tubing connected? (See water flow
diagrams)
8
.
9.
Is the brine valve float set right? (See page 22)
Press the SELECT button 2 times to display the hardness
setting Be sure it is the correct setting for the
household’s water supply. (Make a hardness test of the
raw water and compare with the hardness setting. Also
test a soft water sample to verify if a problem exists.)
Press SELECT twice more to return the time of day
display.
If you do not Find the problem after making initial checks,
do the
Manual
Initiated Electronic Diagnostics, and the
Manual Advance Regeneration Check
19