Solutions to Common Problems
Avoid Service Checklist
Before calling for service, review this list. It may save both time and expense. The list includes common occurrences that
are not the result of defective workmanship or materials in this dryer.
IMPORTANT
Disconnect dryer from electrical service before performing any work on unit or on associated
systems (including electrical supply, gas inlet, water inlet or exhaust venting).
OCCURRENCE
POSSIBLE CAUSE
SOLUTION
Dryer does not start.
Electrical power cord is not securely plugged in or
plug may be loose.
Make sure the plug fits tightly in wall outlet.
House fuse blown or circuit breaker tripped.
Reset circuit breaker or replace fuse.
Make sure electrical line is not overloaded and the dryer is on a
separate circuit.
Thermal limiter tripped.
Call Sears or another qualified service dealer for replacement.
Dryer runs but won’t
heat.
There are 2 house fuses in the dryer circuit. If 1 of the 2
fuses is blown, the drum may turn but the heater will not
operate (electric models).
Replace fuse.
Gas supply valve is not open (gas models).
Check to make sure supply valve is open. See INSTALLATION
INSTRUCTIONS for procedure.
Dryer does not have enough air supply to support the
burner flame (gas models).
See INSTALLATION INSTRUCTIONS.
LP gas supply tank is empty or there has been a utility
interruption of natural gas (gas models).
Refill or replace tank.
Dryer should heat when utility service is restored.
Drying cycle takes too
long, outside of the
Lint filter is clogged with lint.
Make sure all lint has been removed from the dryer lint filter
before starting each cycle.
dryer feels too hot or
smells hot.
Exhaust duct requirements have not been met.
Exhaust duct must be at least 4 inches in diameter and made of
rigid or semi-rigid metal.
When in place, the duct must have no more than four 90°
bends and must not exceed length listed in INSTALLATION
INSTRUCTIONS.
Electric dryer is connected to a 208 volt circuit.
Drying time will be 20% longer than drying on a 240 volt
circuit.
Drying procedures have not been followed.
See "Operating Instructions.”
Outside exhaust hood or exhaust duct may be
clogged or restricted.
Clean out any obstruction.
High humidity.
Use a dehumidifier near the dryer.
Drying cycle stops after
only a few minutes,
leaving load wet
Check Exhaust alerts have been overlooked and the
dryer shuts down after a few minutes.
Immediately inspect your venting system and make any repairs
or perform any cleaning procedures necessary.
Excessive wrinkling.
Dryer is overloaded.
Do not overload. See "Operating Instructions.”
Items left in dryer too long.
Remove items as soon as cycle ends.
Insufficient sorting of items.
See "Operating Instructions.”
Drying temperature too high.
Follow fabric care label instructions.
Scratching or chipping
of the drum finish.
Foreign objects such as coins, pins, clips or buttons are
inside the dryer.*
Always remove foreign objects from pockets before laundering.
Remove objects from drum and restart dryer.
Permanently attached items such as belt buckles,
zippers and fasteners may be hitting the inside of the
drum.*
It may be necessary to sew a scrap of material securely around
ornaments before drying to prevent scratching and damage to
the dryer.
*Drum damage caused by foreign objects or permanently attached items is not covered by the warranty.
18