Fig. 60, Possible problem, Code – Kenmore INTELLISOFT 625.38376 User Manual
Page 36: Procedure for removing error code from faceplate, Fig. 61, Service tech information, Nnrl
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Service Tech Information
The faceplate timer (PWA) computer has a self-diagnostic
function for the electrical system, except put power and
water meter. The computer monitors electronic components
and circuits for correct operation. If a malfunction occurs, an
error code appears in the faceplate display.
The chart below shows the error codes that could appear,
and the possible problems for each code.
FIG. 60
POSSIBLE PROBLEM
CODE
MOST LIKELY
LESS LIKELY
Erri, ЕггЗ, Err4
wiring harness connections at switch and facepiate not connected / position switch inoperabie / motor inoperabie
Err5
facepiate timer (PWA)
While an error code appears in the display, all faceplate
buttons are inoperable except the SELECT1 button.
SELECT 1 remains operational so the service person can
make the MANUAL INITIATED ELECTRONIC DIAGNOS
TICS (below) to further isolate the problem, and check the
water meter.
PROCEDURE FOR REMOVING ERROR CODE
FROM FACEPLATE:
1. • Unplug transformer from outlet.
• Plug in transformer.
• Wait for 8 minutes.
2. • Unplug transformer from outlet.
• Correct problem.
• Plug in transformer.
• Wait for 8 minutes.
The error code will return if the problem was not corrected.
MANUAL INITIATED ELECTRONICS DIAGNOSTICS:
To enter diagnostics, press the SELECT1 button and hold
for three seconds. The display will show valve cycle posi
tion, position switch status (open or closed), and turbine
operation. See Fig. 59.
TURBINE OPERATION;
If no water is flowing through the
softener, the turbine indicator displays three zeros. When
water is flowing, the flow bar scrolls across the display, and
a 000 to 140 count repeats for each gallon of water passing
through the turbine. To check for positive operation of the
turbine if zeros are shown, open a nearby soft water faucet
and observe the turbine count and flow bar. If you don’t get
a reading in the display, with faucet open, pull the sensor
from the valve outlet port. Pass a small magnet back and
forth in front of the sensor. You should get a reading in the
display. If you get a reading, unhook the in and out plumb
ing and check the turbine for binding.
POSITION SWITCH STATUS:
With the valve in service, or
any of the recharge cycles, the switch indicator will show
open, while the valve is rotating from one position to anoth
er, the indicator will show the switch closed. A defect is
probable if indications vary from this pattern.
valve position indicator
number of days
since the last
regeneration
water meter
turbine count
position switch
indicator (open)
VALVE IN SERVICE POSITION
valve position indicator
Ml. II U
LOCU
m'lE REMAINING
I
HDD
U J J ^
minutes of fill
. cycle remaining
- water meter
turbine count
position switch
indicator (open)
VALVE IN RECHARGE POSITION (FILL, IN THIS EXAMPLE)
valve position indicator
(Fill and Brine Flashing)
y___________ minutes of brining
'
.
.-..-1
- time (begins to count
II II L
BRINE
lUU
TIME REMAINING
I
nnrL
UIJU>',
down when valve
reaches brining
position)
water meter
turbine count
position switch
indicator (closed)
VALVE ROTATING FROM ONE RECHARGE POSITION TO
ANOTHER (FROM FILL TO BRINING IN THIS EXAMPLE)
FIG. 61
Questions? Call The Kenmore Water Line 1-800-426-9345