Leak Test
LEAK TEST
To check for leaks, complete the following steps:
CAUTION: To avoid water or air pressure dam
age to softener inner parts, and to flush pipe
chips or other residue from the water pipes, be
sure to do the following steps exactly as
instructed.
1. Fully open two cold, soft water faucets near the
softener.
2. Look at the pictures In Fig. 18 and 19 to deter
mine your kind of bypass valve(s). Place bypass
valve(s) In “bypass” position. On a single valve,
slide the stem inward to bypass. On a three (3)
valve system, close the inlet and outlet valves and
open the bypass valve.
3.
Fully open
the house main water pipe shutoff
valve. Observe steady water flow from both open
faucets.
4. Place bypass valve(s) in SERVICE
EXACTLY
as
follows:
Keep soft water faucets open.
a.
Single Bypass Valve: Slowly,
slide pull the
valve stem outward toward
service,
pausing sev
eral times to allow the softener to pressurize slow
ly-
b.
Three Valve Bypass:
Fully close the bypass
valve and open the outlet valve.
Slowly,
open the
inlet valve, pausing several times to allow the sof
tener to pressurize slowly.
5.
After about three minutes, open a hot water
faucet for about one minute, or until all air is
expelled, then close.
6
.
Close both cold water faucets.
7. Check your plumbing work for leaks and fix right
away if any are found.
Be sure to observe previ
ous caution notes.
NOTE: If this procedure is performed on a new
softener, water coming from the taps may initial
ly be discolored. This normally occurs the first
time water runs through the resin bed. The dis
colored water is not harmful, and the discol
oration will not last more than a few minutes.
HOUSE MAIN WATER
VALVE BYPASS
FOR SERVICE
Close bypass valve.
Open inlet & outlet
valves.
FOR BYPASS
Open bypass valve.
Close inlet & outlet
valves.
FIG. 19
Questions? Call The Kenmore Water Line 1-800-426-9345