Each exhaust vent should enter the
main vent at an angle pointing in the
direction of the airflow. Vents entering
from the opposite side should be
staggered to reduce the exhausted
air from interfering with the other
vents.

The maximum angle of each vent

entering the main vent should be no
more than 30°.

Keep air openings free of dry

cleaning fluid fumes. Fumes create
acids which, when drawn through the
dryer heating units, can damage
dryers and loads being dried.

A ciean-out cover should be located

on the main exhaust vent for
periodically cleaning the exhaust
system.

An exhaust hood should cap the
outside end of the main vent to

prevent exhausted air from refurning

fo the dryers. If an exhausf hood
cannof be used, the outside end of
fhe main vent should have a sweep
elbow directed downward. If the

main vent travels vertically through

the roof, rather than through the wall,

install 180° sweep elbow on the end
of venf at least 2 feet above the
highest part of the building. The
opening wall or roof shall have a
diameter 1/2 inch larger than the
exhaust vent diameter. The exhaust
vent should be centered in the
opening.

exhaust
hood or
sweep
elbow \

wall

horizontal vent

main exhaust vent

-wall

2 ft. min. above
highest point of
building

180“

sweep

' elbow

- main collector vent

Do Not install screening or cap over

end of venf.

Exhaust vent

connection

Determine which direction you need

to attach the exhaust vent to the
dryer. Next, determine the length of
the exhaust vent you will need to

connect the dryer to exhaust hood or
main vent.

To connect exhaust vent
straight out the back —

Attach exhaust vent to dryer vent.
Then connect exhaust vent to
exhaust hood or main exhaust vent.

Use duct tape to seal all joints.

This dryer may be converted to be

exhausted out the right or left side or
through the bottom. To convert the
dryer, one of fhe following kits MUST
be used:

Exhaust Kit No. 279818 (White)
Exhaust Kit No. 279819 (Almond)

Follow the instructions in the kit to

avoid operational and personal

hazard.

Gas Dryer

Gas supply

requirements

WARNING: If the

information in this manual
is not followed exactly, a

fire or explosion may result

causing property damage,
personal injury or death.

— Do not store or use

gasoline, or other
flammable vapors and

liquids in the vicinity of

this or any other

appliance.

— WHAT TO DO IF YOU SMELL

GAS:
• Do not try to light any

appliance.

• Do not touch any

electrical switch; Do not
use any phone in your
building.

• Immediately call your

gas supplier from a
neighbor's phone.
Follow gas supplier's
instructions.

• If you cannot reach your

gas supplier, call the fire
department.

— Installation and service

must be done by a
qualified installer, service
agency or the gas
supplier.

Observe all governing codes and
ordinances.

Post this warning in a prominent
location.
It is recommended that the operator
post, in a prominent location,
instructions for the customer's use in
the event fhe customer smells gas.
This information should be obtained
from your iocal gas supplier.