Section 1 – Safety Recommendations

Because this unit may be under pressure or vacuum, do not attempt to open any

device, doors or panels while fans or blowers are running. The unit has air hoses

and valves with a maximum recommended operating pressure of 100 psig. To

eliminate the danger of bursting, care must be taken to insure maximum desired

pressure is not exceeded.

Before servicing any portion of the compressed air system the air supply must be

shut off and any pressure relieved.

If your unit is equipped with a discharge auger or an airlock assure that chain

guards are installed before start-up and servicing is attempted only after

electrical power is locked out.

While servicing the filter it is very important that there are no open flames,

welding or grinding sparks. Dust laden air could be highly explosive and extreme

care must be taken. Most filter cartridges will burn if exposed to sparks, welding

or open flames.

Before entering any dust collector:

Run cleaning mechanism 20 minutes with the fan off to clean the filter

cartridges.

Completely discharge dust solids from hopper, if applicable.

Shut off compressed air supply and relieve pressure in the compressed air

manifold.

Lock out all electrical power on all equipment especially rotating

equipment.

On toxic operation, purge collector housing and install a blank in the inlet

duct.

Install catwalks and safety cables as required.

Secure access doors in an open position or remove doors.

Use the buddy system.

Wear a respirator or appropriate breathing equipment.

Use common sense.

Follow all current OSHA regulations relative to Lockout / Tag-Out and Confined

Space Entry and any other applicable regulations when servicing your

equipment.

On the following page are examples of safety stickers you will find on Camcorp

equipment. These will help identify potential hazards on the equipment.

1-1