Antari W-530D User Manual
Page 6

- Menu settings with the button
MENU
▪ Setting time intervals for timer operation
Press the button
MENU until the display indicates » Interval Set« . Use the
buttons UP and DOWN to adjust the intervals between the individual fog
outputs in timer mode within the range of 5 and 200
seconds.
▪ Setting the output duration for timer operation
Press the button
MENU until the display indicates » Duration Set« . Use the
buttons UP and DOWN to adju
st the duration of the fog outputs in timer mode
within the range of 1 and 200 seconds.
▪ Setting the fog output volume for timer operation
Pre
ss the button MENU until the display indicates » Timer Output« . Use the
buttons UP and DOWN to adjust the fog output volume in timer mode within
the range of 1 % and 100 %.
▪ Setting the fog output volume for continuous operation
Press the button MENU until the display indicates » Volume Output« . Use the
buttons UP and DOWN to adjust the fog output volume in continuous mode
within the range of 1 % and 100 %.
To set the unit to continuous fog output in continuous mode, select » NON
STOPBURST« below a value of 1 % or above a value of 100 %.
NOTE:
When setting a fog output volume higher than 30 % for continuous
operation, the fog machine occasionally needs to stop the fog output to
reheat. When» NONSTOPBURST« is selected, the fog machine adjusts the fog
output volume and heater temperature automatically and does not need to
stop the fog output to reheat.
▪ Setting the DMX512 address
Press the MENU until the display indicates » DMX512 Address: 001« . Use the
buttons UP and DOWN to set the machine to the same address as on your
DMX controller. Please refer to chapter DMX512 settings for more
information on DMX operation.
▪ Switching the wireless function on and off
Press the button MENU until the display indicates » Wireless ON« . Use the
buttons UP and DOWN to deactivate the wireless function (indication
» Wireless OFF« ) and to reactivate it (indication » Wireless ON« ).
▪Switching the fluid sensor on and off
Press the button MENU until the display indicates » Fluid Sensor Set ON« .
Use the buttons UP and DOWN to deactivate the fluid sensor (indication
» Fluid Sensor Set OFF« ) and to reactivate it (indication » Fluid Sensor Set ON« ).
▪Switching the W-DMX function on and off
Press the button MENU until the display indicates » W-DMX Power ON« . Use the
buttons UP and DOWN to deactivate the W-DMX function (indication » W-DMX Power
OFF« ) and to reactivate it (indication » W-DMX Power ON« ).