beautypg.com

Antari HZ-500 User Manual

Page 6

background image

6

5. Please open the square door on the top of the flightcase before operation in order to let

the haze come out smoothly.

6. Set the power switch to “ON” on the control panel of the machine.

Make sure that the red indicator light is on.

7. There is an intake hole in the back of the flightcase. There are a metal net and a filter attached on

the intake, which can prevent a clogging problem. Please inspect and clean the metal net and filter

periodically.

Caution

1. Always monitor and make sure that there is sufficient haze liquid inside the tank during

operation.

2. When the machine is operated for a longer period of time under open- air conditions, falling

dust/debris might attach to the metal net and filter on the intake hole. The metal net and filter is

serviceable, which means those can be detached easily by screw driver. Please use water to

clean the metal net and filter periodically. By doing this

you

can avoid dust going into the hazers

and prevent the clogging problem of hazers.

3. If you have followed the above operation steps, and you still experience low output, mechanical

noise or no output at all, unplug the unit immediately from the mains. Check the fluid level, the

external fuse, the remote control connection, and the power cable from the wall. If all of the

above appears to be OK, plug the unit in again. If the hazer still does not function, discontinue

operation or it may result in permanent damage to the unit. Return the machine to your Antari

dealer. Always drain tank before mailing or transporting this unit.

4. Please detach the cap on the tank if you want to clean the cap.