Setting time intervals for timer operation, Setting the output duration for timer operation, Setting the fog output volume for timer operation – Antari Z-1200II User Manual
Page 8: Setting the dmx512 address
8
0B
Setting time intervals for timer operation
Press the button FUNCTION until the display indicates »Interval Set«. Use the buttons UP and DOWN to adjust
the intervals between the individual fog outputs in timer mode within the range of 1 and 200 seconds.
1B
Setting the output duration for timer operation
Press the button FUNCTION until the display indicates »Duration Set«. Use the buttons UP and DOWN to
adjust the duration of the fog outputs in timer mode within the range of 1 and 200 seconds.
2B
Setting the fog output volume for timer operation
Press the button FUNCTION until the display indicates »Timer Out«. Use the buttons UP and DOWN to adjust
the fog output volume in timer mode within the range of 1 % and 100 %.
3B
Setting the fog output volume for continuous operation
1. Press the button FUNCTION until the display indicates »Volume Out«. Use the buttons UP and DOWN to
adjust the fog output volume in continuous mode within the range of 1 % and 100 %.
2. To set the unit to continuous fog output in continuous mode, select »NON STOP BURST« below a value of
1 % or above a value of 100 %.
NOTE: When setting a fog output volume higher than 30 % for continuous operation, the fog machine
occasionally needs to stop the fog output to reheat.
When »NON STOP BURST« is selected, the fog machine adjusts the fog output volume and heater
temeperature automatically and does not need to stop the fog output to reheat.
4B
Setting the DMX512 address
Press the FUNCTION until the display indicates »DMX 512 Add.«. Use the buttons UP and DOWN, to set the
machine to the same address as on your DMX controller. Please refer to chapter DMX512 settings for more
information on DMX operation.
-Continuous operation
Press the button VOLUME, to activate continuous fog output. The display indicates »Volume« followed by
The value that was set in menu item »Volume Out« or »NON STOP BURST« when continuous fog output was
selected. To stop the fog output, press the button VOLUME once again.
NOTE: When a fog output volume higher then 30 % was set for continuous operation, the fog machine
occasionally needs to stop the fog output to reheat.When »NON STOP BURST« was selected, the fog machine
adjusts the fog output volume and heater temeperature automatically and does not need to stop to reheat.
-Manual operation
For immediate fog output at the maximum volume of fog, keep the button MANUAL pressed.The display
indicates »Manual 100 %«. As soon as you release the button, the fog output will stop. The manual operation
will take priority over the continuous operation and the timer operation. Even if one of these operating modes is
activated, the fog machine will always emit the maximum volume of fog when the button MANUAL is pressed.
-Timer operation
In the timer mode, the fog machine will automatically emit fog. The time intervals, duration and fog volume
depend on the corresponding menu settings. Press the button TIMER, to activate the timer mode. The display
indicates the set time interval. The unit counts down to 0 seconds and emits fog. To deactivate the timer mode,
press the button TIMER again