3) changing the monitor time, 4) end of setting – A&D Weighing AD-1690 User Manual
Page 14

12
* If the quantity value of pressure change is
insufficient when measuring, “fa1l” may be 
displayed by changing the measurement system 
pressure (Leak Tester, adapter, attachment).
(3) Changing the monitor time
The leak tester judges the leak by the monitor 
time.
(Unit: second)
Changing the minimum value is by 0.5 seconds. 
(
Factory setting: 3.0 seconds)
Change the value by using the
D
UP
N
or DOWN key.
* The value displayed with the “○” mark (left side
of the display) is the value in memory. But while 
changing the displayed value, the “○” mark is 
turned off.
Press the SET key to store the value.
After setting finish,
“
SET
end
”
is displayed for
approximately 1 second. (the
“
end
”
is flashing)
 
 
(4) End of setting
The Leak Tester returns to the measurement 
standby mode by non-operation, or by pressing the 
SET key, to memorize the setting value changed
with “(2), (3)” above.
 
 
 
 
 
 
 
 
 
 
 
 
 
REDY
Press
Store
SET
kPa
S E C
SET
UP
DOWN