Ip printer retry behavior, Enhanced message flow information – Kofax Communication Server 9.1.1 User Manual
Page 7
Changes in Behavior
Kofax Communication Server Release Notes
7
For more information, see:
▪ TC Probe Manual, version 1.01.00 edition 2
Chapter Installation, Configuration, Maintenance - Installation Steps
Chapter Probe-Specific TCLINK Configuration Options - Probe SMS Messages
IP Printer Retry Behavior
The retry behavior of KCS IP Printer can now be configured to reduce the priority of
print jobs that fail to print on the first attempt. Use the new configuration parameter
TcPriorityChange to enable this feature. The default behavior is unchanged. (SPR00072418)
For more information, see:
▪ KCS IP Printer Manual, version 2.10.01 edition 1
Chapter Installation
Enhanced Message Flow Information
TCLINK can now write message flow information into four custom fields of TCOSS send
orders. The following registry values under HKLM\SOFTWARE\TOPCALL are now
available for each link instance and define which information is stored in the custom fields:
(SPR00090085, SPR00090101)
▪ CorrAddress - Custom field ID to store the original sender address
▪ CorrLinkName - Custom field ID to store the link instance name, in syntax “Computer
\LinkInstance”
▪ CorrLinkQueue - Custom field ID to store the default queue name of the link that received
the message
▪ CorrMapped - Custom field ID to store information about success or failure of shadow user
lookup (yes means success, no means failure)
In each registry value, you can specify the custom field where the information should be
stored (1..4). If you set a value to 0, that information is not saved.
Multiple restrictions apply:
▪ A link exit might overwrite the custom fields before the message is posted.
▪ Send orders posted via applications other than links might hold custom field information
with different meaning.
▪ TCLINK does not write custom field information into immediate replies to TC/Probe.
▪ Custom field values may get truncated by TCOSS. Each field can have 128 characters, but
the total length of all four custom fields is limited to 320 characters.
TC/Report stores this information in its database and it can now display it in its UNIV and
UNIV_GRAPH reports.
TCOSS copies custom fields from the original send order to all events, notifications and send
copy messages triggered by that send order. Therefore, there is a new parameter WithNotifs
in UNIV and UNIV_GRAPH. Set WithNotifs to NO to eliminate notifications and sending
copies for messages from non-KCS users. Set WithEvents to NO to eliminate events triggered