Jaclo Thermostatic Valve, Rough - J-TH34 User Manual
Page 7

jaclo
industries | 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133
JACLO.COM | PG 7
CREATED 5.2014
| PG 7
ITEM QUANTITY
DESCRIPTION
NOTES
1
1
Thermostatic Body
2
1
Thermostatic Cartridge
3
1
Thermostatic Cartridge Locknut
4
1
Thermostatic Limit Stop Ring
5
1
"C" Clip
6
2
Limit Stops
7
1
Cold Check Stop Assembly
8
1
Hot Check Stop Assembly
9
2
Check Stop Locknut
10
1
Sleeve
Supplied w/ Trim Kit
11
1
Dial Pointer
Supplied w/ Trim Kit
12
1
Spline Adapter
Supplied w/ Trim Kit
13
1
Diverter Body
14a
1
2 Way Diverter Cartridge
14b
1
3 Way Diverter Cartridge
15
1
Diverter Locknut Assembly
16
1
Thermostatic with VC Body
17
1
Thermostatic with VC Cartridge
SYSTEM REQUIREMENTS
• This thermostatic valve is designed for use with pressurized hot & cold water supplies only and should not be
used with low-pressure storage heating sytems.
• This valve was factory set to 100°F maximum at a pressure of 45 PSI. The actual temperature must be checked
due to water temperature & pressure deviations.
Pressure
1/2”
Valve
1/2” NPT inlets and outlets
Recommended range-
30PSI - 70 PSI
Temperature
3/4” Valve
3/4” NPT inlets and outlets
Hot water inlet-
165°F Max., 130°F Min.
Marked dial range-
70°F - 120°F
Safety stop-
Adjustable