Tm-u295 ticket printer, Tm-u590 ticket printer – Hardy Enviro Bench Scales User Manual
Page 2
TM-U295 Ticket Printer
The Enviro™ Series should be programmed for Port 1
Output button, 9600 baud, 8 data bits, no stop bits, and
Hibusy.
Set the printer’s dip switches per the following:
Enviro™ DB25
1 and 3 on, the rest off.
TM-U590 Ticket Printer
The Enviro™ Series should be programmed for Port 1
Output button, 9600 baud, 8 data bits, no stop bits, and
Hibusy
Enviro™ DB25
Printer dip switch settings:
DSW 1: 1, 3, and 7 on only.
DSW 2: All off.
0596-0317-01 Rev. A Page 2