iii. The entire under and accept section leds will be lit and the first of the

over section. Adjust the value displayed to be equal to the low end of the
over range. Press enter to accept.

iv. The entire bar graph will be lit. Adjust the displayed value to be equal to

the high end of the over range. Press enter to accept.

c. The display will briefly display CSaved and return to weight display.
d. Repeat these steps for the other recipes if needed.



Check Weighing operation

1. Select the check weigh recipe 1-4 you wish to use by pressing the 1-4 button.

a. Recipe led should light.

2. Place weight on scale.

a. Leds will light based on weight.

i. If only amber leds, then under weight

ii. If all amber and any green and no red, then acceptable

iii. If all amber and green and any red, then over weight.



Accumulator and Serial output

1. There are four settings to select from

a. Auto accumulate and auto print

i. Set serial port output to Auto under Setup menu

ii. Set Aout to Y under APP menu

b. Auto accumulate and manual print

i. Set serial port output to Auto under Setup menu

ii. Set Aout to N under APP menu

c. Manual accumulate and auto print

i. Set serial port output to button under Setup menu

ii. Set Aout to Y under APP menu

d. Manual accumulate and manual print

i. Set serial port output to button under Setup menu

ii. Set Aout to N under APP menu

2. When place weight on scale, and it comes out of motion

a. If Selection a above (auto/auto),

i. Will automatically add weight to accumulator even if out of range

ii. Will automatically send output from serial port