5 | compressor assembly – GEA Bock HGZ7 User Manual
Page 17

D
GB
F
E
17
09726-11.2014-DGbF
1 Liquid subcooler 5
Expansion valve
FUA
Liquid subcooler,
2 Filter drier 6
Temp. sensor expansion valve
Outlet
3 Solenoid valve 7
Pressure compensation connection
FUE
Liquid subcooler,
4 Sight glasses
Inlet
Ø 16 mm
Ø 16 mm
Dia. 16 mm
Dia. 16 mm
Dia. 6 mm
Dia. 12 mm
Dia. 12 mm Dia. 12 mm
from the receiver
FUE
Heat
insulation
Fig.21
to the evaporator
5| Compressor assembly
5.4 Installation example, liquid subcooler with accessories
INFO
General notes:
Sensor lines, wires, etc. should not be attached with cable
binders directly to pipes or frames; otherwise, the thin pipes
may be worn through. It is better to run them through spiral
protective tubes.
If the compressor will be set up outside, UV-resistant materials
should be used.
Line B
Line A
Line B
Dia. 16 mm
Intermediate pressure
chamber MP