beautypg.com

8 | technical data – GEA Bock HG34e User Manual

Page 24

background image

24

D
GB
F
E
I
Ru

96178-11.2014-DGbFEIRu

8| Technical data

Ty

pe

No.

of

cylin

-

ders

Displace

-

ment

50

/

60

Hz

(1450

/ 1740

rpm

)

Electrical data

W

eight

Co

nn

ec

tio

ns

Oil

charge

Sound pres

-

sure level

Voltage

Max.

Operating current

/ Y

Max.

power

consump

-

tion

Starting

current

(rotor

locked)

/ Y

Dis

-

charge

line

DV

Suction

line

SV

m

3

/h

A

kW

A

kg

m

m

(in

ch

)

m

m

(in

ch

)

Lt

r.

dB

(A

)

HG3

4e

/2

15

-4

4

18

,8 / 2

2,

6

14

,0 / 8

,1

4,

8

87 / 5

0

92

22 (

7

/

8

)

28 (

1

1

/

8

)

1,

3

62 / 5

9 / 5

8

HG3

4e

/2

15

-4

S

18

,8 / 2

2,

6

18,3 / 10,5

6,0

13

2 / 7

6

97

62 / 5

9 / 5

8

HG3

4e

/2

55

-4

22

,1 / 2

6,

6

17

,0 / 9

,8

6,0

87 / 5

0

91

64 / 6

2 / 6

0,

5

HG3

4e

/2

55

-4

S

22

,1 / 2

6,

6

21

,1 / 1

2,

2

7,2

13

2 / 7

6

96

64 / 6

2 / 6

0,

5

HG3

4e

/3

15

-4

27

,3 / 3

2,

8

21

,1 / 1

2,

2

7,4

111

/ 6

4

94

66 / 6

4 / 6

3

HG3

4e

/3

15

-4

S

27

,3 / 3

2,

8

25

,5 / 1

4,

7

8,9

13

2 / 7

6

97

66 / 6

4 / 6

3

HG3

4e

/3

80

-4

33

,1 / 3

9,

7

26

,1

/ 1

5,

1

9,3

111

/ 6

4

93

67 / 6

4,

5 / 6

4

HG3

4e

/3

80

-4

S

33

,1 / 3

9,

7

31

,2 / 1

8,

0

11,1

13

2 / 7

6

96

67 / 6

4,

5 / 6

4

1

2

3

2

4

220-240 V

∆ / 380-420 V Y - 3 - 50 Hz

265-290 V

∆ / 440-480 V Y - 3 - 60 Hz

L / M / H

5

Tolerance

10%)

rela

tive

to

the

mean

value

of

the

volta

ge

range.

Other

volta

ges

and

types

of

current

on

request.

-

Th

e

sp

ec

ifi

ca

tio

ns

fo

r ma

x.

p

ow

er

c

on

su

m

pt

io

n

ap

pl

y

fo

r 5

0H

z

op

er

at

io

n.

Fo

r 6

0H

z

op

er

at

io

n,

th

e

sp

ec

ifi

ca

tio

ns

h

av

e

to

b

e

m

ul

tip

lie

d

by

th

e

fa

ct

or

1.

2. T

he ma

x. w

or

kin

g c

ur

re

nt r

ema

in

s u

nc

ha

ng

ed

.

-

Take account of the max.

opera

ting current / max.

po

wer consumption for

design of fuses,

supply lines and safety devices.

Fuse:

Consumption

ca

tegor

y AC3

1

2

All

specifica

tions

are

based

on

the

a

vera

ge

of

the

volta

ge

range

For solder connections

L

=

lo

w

tempera

ture

(-35

/

40

°C),

M

=

normal

cooling

(-10

/

45

°C),

H

=

air

conditioning

(5

/

50°C)

sound pressure level measured in

lo

w

reflection

measuring

area,

measuring

distance

1m.

Compressor

opera

tion

a

t 50

Hz

(1450

rpm),

refrigerant

R404A.

Values

sta

ted

are

a

vera

ge

values,

tolerance

±

2

dB(A).

5

3

4