7.2 Work to be carried out

7| Maintenance

In order to guarantee optimum operational reliability and service life of the compressor,

we recommend

carrying out servicing and inspection work at regular intervals:

Oil change:

-

not mandatory for factory-produced series systems.

-

for field installations or when operating near the application limit: for the first time after 100
to 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.
Dispose of used oil according to the regulations; observe national regulations.

Annual checks: Oil level, leak tightness, running noises, pressures, temperatures, function of
auxiliary devices such as oil sump heater, pressure switch.

HG8 / ...

2470-4 (S)

2830-4 (S)

3220-4 (S)

Designation

Item No.

Item No.

Item No.

Set of gaskets kit

80235

Valve plate kit

80199

Oil pump kit

80290

Oil sump heater kit (220-240 V)

80237

Only use genuine GEA Bock spare parts!

7.3 Recommended spare parts

7.1 Preparation

WARNING

Before starting any work on the compressor:

Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!

After maintenance has been performed:

Connect safety switch.
Evacuate compressor.