beautypg.com

System a - 100, A-116, Controls – Doepfer A-116 VC Waveform Processor User Manual

Page 3: Doepfer

background image

doepfer

System A - 100

VC Waveform Processor

A-116

3

3. Controls

1

Lev.

The input amplifier’s gain can be set with attenuator
1

. Since the gain amount is variable from 0 up to a

factor of 2, you can attenuate as well as amplify input
signals.

2

Clipping Level

With control 2, you set the clipping threshold level
in a range from -10 V to +10 V. Any part of a
waveform which was above this threshold is clipped -
that is, held at the threshold level (see Fig.1).

3

CCV

If you want to use a CV at input " to control or
modulate the clipping threshold, set the clipping con-
trol voltage level
with Attenuator 3.

4

SCV

Symmetry can likewise be controlled or modulated by
voltage control. Use attenuator 4 to control the
level of the symmetry control voltage at input §.

5

Sym.

Symmetry, that is the gain factor of the internal
symmetry VCAs
, is altered by control 5. The Sym-

metry VCA is a special amplifier which operates in the
amplification range from -1 to +1, so can amplify
negative as well as positive voltages (see Fig. 2).

Fig. 1: how the clipping level works

0

Clipping

Level

0

Clipping

Level