COP-USA ASH56NVIR-L36S User Manual
Page 16

14
VIII. Normal Troubles and Remedies
Troubles
Possible Causes
Remedies
No action and images after
switching on
Power supply
damaged of
insufficient electric
power
Replace
Wrong connection of
power supply wires
Make correction
Engineering circuits
failed
Remove
Abnormal self-inspection,
images with humming of
motor
Mechanic trouble
Repair
Pan/tilt may be
inclining
Re-fix
Insufficient electric
power
Replace with qualified power supply
Normal self-inspection, no
images
Wrong connection of
VF circuit
Make correction
Bad contact of VF
circuit
Remove
Camera damaged
Replace
Successful self-inspection
without control
Wrong connection of
control signal wires
Make correction
Mismatched address
Re-select
Mismatched
protocol Make mismatch of protocol and
controller and restart
Unstable images
Bad contact of VF
circuit
Remove
Insufficient electric
power
Replace
Dome pan/tilt out of
control
Abnormal
self-inspection
Restart
Bad contact of control
circuit
Remove
Operation of main
machine has problem
Restart the main machine
Much load or
communication
distance too far
1. Connect 120Ω resistor of the
farthest dome pan/tilt from the
controller and disconnect all
other resistors;
2. Add coding divider
Auto/Manual of laser lamp
ineffective
laser lamp may be
damaged
Rework
Some common troubles and their causes and remedies are listed above for your reference. Should you meet
other special problem, you can contact with the dealer directly for technical support.