Checkline TI-25DL User Manual
Page 3
– 3 –
3.0
O
VERVIEW
O
F
G
AUGE
3.1 Gauge
Probe
Receptacles
Red LED
Green LED
Probe Zero Test Plate
(battery compartment cover)
Serial Output
Port
Backlit LCD
Display
Bottom of Gauge
Probe
– 34 –
13.0 M
ATERIAL
S
AFETY
D
ATA
S
HEET
(MSDS)
Section 1— Product Identification
Product Name: TI-25DL
Generic Name: Ultrasonic Couplant
Manufacturer: Electromatic Equpt. Co.
NFPA Hazardous Materials Identification System (est)
Health 0 Flammability 0 Reactivity 0
Section 2— Hazardous Ingredients
This material does not contain any ingredients having known health hazards in concentrations
greater than 1%. This material does not contain any known or suspected carcinogens.
Section 3 — Physical Data (nominal)
Boiling Point: >220°F
Freezing Point: <20°F
Vapor Pressure: N/A
Evaporation Rate: N/A
Specific Gravity: >1.0Z
Solubility in Water: complete
pH: 7.35 – 7.9
Acoustic Imp.: 1.726 x 10
6
Vapor Density: N/A
Appearance and Odor: water white, opaque gel; bland odor
Section 4 — Fire and Explosive Hazard Data
Flash Point: none Upper Exposure Limit: none Lower Exposure Limit: none
Special Fire Fighting Procedures: N/A
Extinguishing media: N/A
Unusual Fire and Explosion Hazards: none
Section 5 — Reactive Data
Stability: Stable Conditions to Avoid: none
Incompatibility (Materials to Avoid): none known
Hazardous Polymerization: will not occur
Hazardous Decomposition or Byproducts: none known
Section 6 —- Health Hazard and First Aid Data
Routes of Entry
1
:
Skin: not likely Ingestion: not normally
Eyes: not normally
Inhalation: no
Effects of Overexposure:
Acute: May cause temporary eye irritation
Chronic: none expected
First Aid Procedures:
Skin: Remove with water if desired.
Eyes: Flush with water for 15 minutes.
Ingestion: For large quantities, induce vomiting and call a physician Inhalation: N/A
Section 7 - Storage and Handling Information
Precautions to be taken in handling and storage: Store between 20 °F and 120 °F. Spills are
slippery and should be cleaned up immediately. Steps to be taken in case material is released or
spilled: Pick up excess for disposal. Clean with water. Waste disposal method: Dispose of in
accordance with federal, state, and local regulations.
Section 8 — Control Measures
Respiratory Protection: not required
Ventilation: not required
Protective Gloves: on individuals demonstrating sensitivity to TI-25
Eye Protection: as required by working conditions
Other Protective Equipment: not required
1. TI-25DL contains only food grade and cosmetic grade ingredients.
Membrane