4.0 I

NSTALLING

/C

HANGING THE

B

ATTERIES

1. If strobe is ON, switch the power OFF by pressing and holding the

button (see pages 3 and 4) for 3 seconds.

2. Unscrew the 2 screws at back of the strobe and remove the battery

compartment cover.

3. Insert 3 new, fully charged AAA batteries into the battery

compartment, following the polarity marked on the case.

4. Replace the battery cover and screws.

Do not overtighten.

NOTE: Disposable or rechargeable (NiMH) batteries may be used.

– 16 –

Step 2:

As the flash rate is lowered, three singular harmonic images
are found.(The first image at 9,600 RPM is rejected because it
is a double image). Point "X" is 7,200, point "Y" is 4,800 and
Point "Z" is 3,600.

Step 3:

To calculate the true RPM, enter these values into one of
the equations shown below. For this example, we will use
equation (6).

RPM

= 2AB(A+B)/(A-B)2
= 2x2,400x1,200x(2,400+1,200)/

(2,400-1,200)2

= 14,400

Where A = (X-Y)

= 7,200 - 4,800
= 2,400

And B = (Y-Z)

= 4,800 – 3,600
= 1,200

Therefore, the true speed of the object is 14,400 RPM. To help further
illustrate this point, the figure below shows the harmonic relationship of
the four images found in this example:

If TWO points, “X” and “Y” are

recorded:

(1) *RPM = XY/(X-Y)
(2) *RPM =Sx(Sx+1)(X-Y)
(3) RPM =S (S -1)(X-Y)
(4) *Sx = Y/(X-Y), rounded
(5) Sy = X/(X-Y), rounded

If THREE points, “X,” “Y” and “Z”

are recorded:

(6) *RPM = 2AB(A+B)/(A-B)2
(7) *A= (X-Y)
(8) *B (Y-Z)

Variations of THREE point formulas:

(9) *RPM = 2PS/D2
(10) P = Product, (A*B)
(11) S = Sum, (A+B)
(12) D = Difference, (A-B)
(13) *Sx = 2(Y-Z)/(X+Z-2Y)

(14) Sy = (X-Z)/(X+Z-2Y)
(15) Sz = 2(X-Y)/(X+Z-2Y)

(16) *Sx = 2B/(A-B)

(17) Sy = (A+B)/(A-B)

(18) Sz = 2A/(A-B)

(19) Sx = 2B/D

(20) Sy = S/D

(21) Sz = 2A/D

Depending on the accuracy desired, either two or three harmonic points
can be found. These points are used in one of the following equations:

Formulas for calculating “Out of Range” RPMs.

Harmonic

FPM/RPM

1/4

1/3

1/2

2/3

5/6

1/1

3,600

4,800

7,200

9,600

12,000

14,400

This manual is related to the following products: