beautypg.com

California Faucets StyleTher - TO-THCN-XX User Manual

Page 2

background image

TO-THN-XX_ii_120227.doc

Pg

2

1

2

TEMPERATURE SETTING

• Remove SCREW (2), WASHER (3), MUDGUARD

(4) and SLEEVE (5) from installed VALVE (1)

• Push plastic TEMPERATURE LIMIT STOP (6) onto

THERMOSTATIC CARTRIDGE (7) as shown

• Temporarily place BONNET (8) onto

THERMOSTATIC CARTRIDGE STEM (7a)

• With both hot and cold water supplies on, open

stop/volume control valve to one output device

• Use temperature measuring device to confirm

temperature is 100°F when BONNET (8) button is

positioned straight up at 12 o’clock

• When button on BONNET (8) is depressed and

rotated full left (CCW), the maximum temperature
discharged from valve will be 115°F (Note: Follow

all applicable local plumbing codes when setting

maximum discharge water temperature)

• Carefully remove BONNET (8) and place aside

until trim is installed

Note: If temperature is not 100°F with BONNET (8),

button at 12 o’clock, the CARTRIDGE STEM (7a) must

be rotated to change temperature setting (clockwise
(CW) for cooler & counter-clockwise (CCW) for

warmer)

WARNING: Forcibly rotating thermostatic cartridge stem prior to
installing handle trim, will damage cartridge and void warranty.

INSTALL

TRIM

• Position FACEPLATE (9) onto CARTRIDGE NUT

(10) as shown

• Install SLEEVE (11) onto CARTRIDGE NUT (10)

and tighten to secure FACEPLATE (9) against

shower wall

• Place BONNET (8) onto THERMOSTATIC

CARTRIDGE STEM (7a)

• Secure BONNET (8) with SCREW (12)
• Place HANDLE (13) onto BONNET (8) and

tighten handle SETSCREW (14)

Note: Depending on handle style, it may be necessary

to cut BONNET STEM (8a) and SCREW (12) to allow
HANDLE (13) to fully seat against BONNET (8)




CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED BY

A LICENSED PROFESSIONAL

100°F

Rotate CW for Cooler (shown)

Rotate CCW for Warmer

This manual is related to the following products: