California Faucets StyleTher - TO-THCN-XX User Manual
Page 2

TO-THN-XX_ii_120227.doc
Pg
2
1
2
TEMPERATURE SETTING
• Remove SCREW (2), WASHER (3), MUDGUARD
(4) and SLEEVE (5) from installed VALVE (1)
• Push plastic TEMPERATURE LIMIT STOP (6) onto
THERMOSTATIC CARTRIDGE (7) as shown
• Temporarily place BONNET (8) onto
THERMOSTATIC CARTRIDGE STEM (7a)
• With both hot and cold water supplies on, open
stop/volume control valve to one output device
• Use temperature measuring device to confirm
temperature is 100°F when BONNET (8) button is
positioned straight up at 12 o’clock
• When button on BONNET (8) is depressed and
rotated full left (CCW), the maximum temperature
discharged from valve will be 115°F (Note: Follow
all applicable local plumbing codes when setting
maximum discharge water temperature)
• Carefully remove BONNET (8) and place aside
until trim is installed
Note: If temperature is not 100°F with BONNET (8),
button at 12 o’clock, the CARTRIDGE STEM (7a) must
be rotated to change temperature setting (clockwise
(CW) for cooler & counter-clockwise (CCW) for
warmer)
WARNING: Forcibly rotating thermostatic cartridge stem prior to
installing handle trim, will damage cartridge and void warranty.
INSTALL
TRIM
• Position FACEPLATE (9) onto CARTRIDGE NUT
(10) as shown
• Install SLEEVE (11) onto CARTRIDGE NUT (10)
and tighten to secure FACEPLATE (9) against
shower wall
• Place BONNET (8) onto THERMOSTATIC
CARTRIDGE STEM (7a)
• Secure BONNET (8) with SCREW (12)
• Place HANDLE (13) onto BONNET (8) and
tighten handle SETSCREW (14)
Note: Depending on handle style, it may be necessary
to cut BONNET STEM (8a) and SCREW (12) to allow
HANDLE (13) to fully seat against BONNET (8)
CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED BY
A LICENSED PROFESSIONAL
100°F
Rotate CW for Cooler (shown)
Rotate CCW for Warmer