Ethernet Cables
• 47
Note: It's important that each pair is kept as a pair. TX+ & TX-
must be in one pair, and RX+ & RX- must together in another
pair. (Just as the table above shows).
This is how the pairs are named:
The + side of each pair is called the "tip" and the - side is called the "ring",
a reference to old telephone connectors.
Cross-Over Cable
This cable can be used to cascade hubs, or for connecting two Ethernet stations back-to-back without a hub.
It works with both 10Base-T and 100Base-TX.
(RJ45 MALE CONNECTOR To network interface card 1)
(RJ45 MALE CONNECTOR To network interface card 2)
Note 1: It's important that each pair is kept as a pair. TX+ & TX- must be in
one pair, and RX+ & RX- must be together in another pair. (Just as the table
above shows).
Note 2: You could also connect 4-4, 5-5, 7-7, 8-8.
Name Pin Cable Color
Pin Name
TX+
1
White/Orange 1
TX+
TX-
2
Orange
2
TX-
RX+
3
White/Green
3
RX+
4
Blue
4
5
White/Blue
5
RX-
6
Green
6
RX-
7
White/Brown
7
8
Brown
8
Pair Pins
Common color
1
4 & 5
Blue
2
1 & 2
Orange
3
3 & 6
Green
4
7 & 8
Brown
Name NIC1
NIC2 Name
TX+
1
3
RX+
TX-
2
6
RX-
RX+
3
1
TX+
RX-
6
2
TX-