Installation spare parts, Spare parts, What to do if – STIEBEL ELTRON SunWarmth CIR 400-2 O User Manual
Page 21: 4 specification table, Cir infrared heater| 21 en g l is h, The appliance does not heat up
![background image](/manuals/654397/21/background.png)
WWW.STIEBEL-ELTRON-USA.COM SUNWARMTH
™
CIR INFRARED HEATER|
21
EN
G
L
IS
H
INSTALLATION
SPARE PARTS
11.4 Specification table
Model
CIR 150-1 I
CIR 150-1 O
CIR 200-2 O
CIR 400-2 O
Item No.
234047
234048
234049
234050
Usage
indoor only
indoor/outdoor
indoor/outdoor
indoor/outdoor
Testing standard
ANSI/UL 1278
ANSI/UL 1278
ANSI/UL 2021
ANSI/UL 2021
Voltage, 60Hz
115–120 V
115–120 V
230–240 V
230–240 V
Wattage
1.5 kW
1.5 kW
2.0 kW
4.0 kW
Amperage
12.5 A
12.5 A
8.3 A
2 x 8.3 A
Required number and size of
circuit breakers
N/A
N/A
15 A
2 x 15 A
Required wire size
(copper)
14 AWG
14 AWG
12 AWG
12 AWG
Lamp temperature
2420 °F, ±360 °F
1325 °C, ±200 °C
2420 °F, ±360 °F
1325 °C, ±200 °C
2420 °F, ±360 °F
1325 °C, ±200 °C
2420 °F, ±360 °F
1325 °C, ±200 °C
Lamp life
(normal conditions)
5000 hours
5000 hours
5000 hours
5000 hours
Lamp color temperature
1600 K, ±200 K
1600 K, ±200 K
1600 K, ±200 K
1600 K, ±200 K
Height
5
11
/
16
˝ / 145 mm
5
11
/
16
˝ / 145 mm
5
11
/
16
˝ / 145 mm
5
11
/
16
˝ / 145 mm
Width
15
9
/
16
˝ / 395 mm
18
9
/
16
˝ / 471 mm
18
9
/
16
˝ / 471 mm
38 ½˝ / 978 mm
Depth
4
7
/
16
˝ / 112 mm
4 ¼˝ / 108 mm
4 ¼˝ / 108 mm
4
7
/
16
˝ / 112 mm
Weight
4.85 lb / 2.2 kg
5.5 lb / 2.5 kg
5.5 lb / 2.5 kg
8.8 lb / 4.0 kg
IP-Rating
IP20
IP24
IP24
IP24
Protection class
I
I
I
I
Color
alpine white
alpine white
alpine white
alpine white
12. Spare Parts
Model
Protective grill
Heat Lamp
CIR 150-1 I
BHSG
LGHS1520 120V
CIR 150-1 O
BHSG
LGHS1524 120V
CIR 200-2 O
BHSG
LGHS2024 240V
CIR 400-2 O
BHSG
(2) LGHS2024 240V
13. What to do if ...
... the appliance does not heat up:
»
For 120 V models, ensure that the unit is plugged into a properly
grounded 120 V wall outlet and that the timer switch is on.
»
For 240 V models, ensure that the timer switch is on and that
there is adequate power available at the circuit breaker and that
the breaker hasn’t tripped. Check for faulty breaker(s).
... you notice a smell:
»
For a short time after initial installation or after a long period
of inactivity, the unit may produce a smell. This is normal and
will not last long once regular operation resumes.
If you cannot remedy the fault, contact your contractor. To facilitate
and speed up your enquiry, please provide the number on the type
plate (Nr. XXXXXX - XXXX - XXXXXX)