Joystick controllers – OEM Controls Superflex 4 User Manual
Page 7

file: SF4MAN.DOC
-
7 -
December 30, 1996
Joystick Controllers
Figures 6 and 7 show typical single and dual axis joystick controllers with Digisensors. Typically, the
Digisensors are pre-wired to terminal blocks on the joystick. (Refer to instructions that come with your
custom joystick controller for proper mounting and grounding procedures).
There are six inputs on the Superflex 4 Controller that may be connected to Digisensors mounted on
joystick controllers. (Usually, only the first four inputs are used). Figure 8 shows the wiring of a typical
single axis joystick. This device is connected to the Superflex 4 as follows -
"
Terminal 1 is connected to power (the +12 volt battery).
"
Terminal 2 is connected to one of the Digisensor inputs on the Superflex connector BT2.
The joystick controller may be located up to 500 feet from the Superflex 4 Controller.
Figure 6
Figure 7
Figure 8