Getting started with the new Survey equipment
Measuring with the default configuration, continued
Some basic decisions have to be
made in this panel:
Which configuration set should be
activated, which job the raw data
should be stored and which antenna
set-up should be used.
A Configuration Set (Config Set) is a
collection of sensor parameters
needed to perform a certain opera-
tion, like data recording rates, point id
templates, data formats, antenna
types, coding methods, etc.
Several default configuration sets
exist which cover standard survey
scenarios. How to create new con-
figuration sets is described in a later
chapter as well as in the Technical
Reference Manual.
For static survey you should select
the PP_STAT configuration set. You
can make this selection either by
using the cursor left key to toggle
between all available configuration
sets until PP_STAT appears or you
can highlight the input field and press
ENTER. Then a list box comes up
showing all available sets:
Step 4: Begin a Survey
Enter the Survey operation by either
pressing 1 in the Main\ panel or by
first navigating to 1 Survey via
cursor keys and then pressing
ENTER or F1 CONT.
The following panel will appear: