5
Manual Setup
First Time Communications Setup
NOTE: Follow these instructions only if the PPC and the DISTO failed to connect as
described in the previous section.
The setup procedure described in this section may be required for certain devices. If the PPC
does not connect to the DISTO device as described in the previous section, the communication
settings in PlusDraw must be changed to match the settings found on the PPC. After these
settings are made, reattempt connection of the PPC to the DISTO as described in the previous
section.
Determine Outbound COM Settings
Access the Bluetooth Settings for the PPC, and locate the Serial Port settings. Make a note of
the Outbound COM Port value as shown in
image 8
.
Tap OK.
Set COM Settings in PlusDraw
Open the PlusDraw program (Start | Programs | PlusDraw) and set the COM setting to match
the outbound COM setting for the PPC.
Tap the Bluetooth Icon (or the
equivalent for your device)
and then Bluetooth Settings
Remember this value
Tap on the icon.
Set to match the PPC’s
outbound COM port setting.
Image 7
Image 8
Image 9
Image 10