Gp output table – Dynon Avionics FlightDEK-D180 Pilots Users Guide User Manual
Page 100
Appendix
11-4
FlightDEK-D180 Pilot’s User Guide
GP output table
General purpose inputs have a unique format in the data output stream. As shown in the table above, they each have 8
characters. 3 are used as a label for the function; 5 are used for the data. As noted above, general purpose inputs sourced
from the HS34 are not included in this table.
Description
Units
Label (3-Bytes)
Example (5-Bytes)
Unused
N/A
XXXXX (‘X’s are output as place holders)
OAT
ºF
OAT
00123 (123 ºF) or –0123 (-123 ºF)
Carb Temp
ºF
CRB
00123 (123 ºF) or –0123 (-123 ºF)
Coolant Temp
ºF
CLT
00123 (123 ºF) or –0123 (-123 ºF)
Coolant Pressure
PSI
CLP
00123 (12.3 PSI)
Fuel Level 3
Gallons x 10
FL3
00123 (12.3 gal)
Fuel Level 4
Gallons x 10
FL4
00123 (12.3 gal)
CHT CHT
Aileron Trim
% of full
deflection
TRA
0061 (61%)
Elevator Trim
% of full
deflection
TRE
0061 (61%)
Rudder Trim
% of full
deflection
TRR
0061 (61%)
Flap Position
º
FLP
00010 (10º)
As an example, the following is one line of EMS data:
0012224826351340262441240122631320562191191OAT00090TRE-0061FLP0001020481378139214
061421143514503583533633743843951103D2