beautypg.com

Dillon DynaSwitch User Manual

Page 10

background image

10

2-3
Dynaswitches &
Reeving Setups

Below are some examples of hoist and reeving setups which use the
Dynaswitch for control and/or safety purposes.

Figure 2-A

2 ropes, 2 part single

reeving

With two parts of line to the hook,
the Dynaswitch should be installed
in series between wire rope and its
dead end point. Microswitch is set
for ½ maximum capacity of the
hoist.

Figure 2-D

The Dynaswitch may also be placed
between hoist and trolley with
microswitch set for maximum
capacity of the hoist and trolley.

Figure 2-B

Figure 2-C

4 ropes, 4 part single

reeving

As shown at right, Dynaswitch is
installed in series with rope to the
dead end. The microswitch is set
for ¼ capacity of the crane because
there are four parts of line to the
hook.

Frictional reactions within the
sheaves may prevent all parts
of the lines from having identi-
cal tension. While generally
suitable for overload protection,
it may give unsatisfactory
results for weighing or batch
control.