9-2

Alarm Contact Output

Connector
6 Position Terminal Block
Rating
1.0A @ 42VAC or 700mA @ 60VDC

Performance

Composite Error Rate < 10

-10

Optical Interfaces

(850nm, LED), ST connector
(1310nm/1550nm Laser), ST, FC/PC , SC connectors

Management

Local Terminal (VT100)
GUI through the chassis DMM only
SNMP option for stand alone

Test Functions

Local Loopback, Remote Loopback,
Remote Loopback with BERT, Bi-directional
Loopback, Continuous Self Test

Loss Budgets

(Guaranteed Loss Budgets. Typical loss budgets are

2dB

greater)

1550nm Laser SMF

26dB

1310nm Laser HP, SMF/MMF

26dB

1310nm Laser SMF/MMF

17dB

850nm LED on MMF

16dB

9.1 Regulatory Compliance

ETL, cETL (UL 60950/CSA C22.2 No. 60950)

EN 60950, EN 60825-1

FCC Part 15B, Class A

EN 55022, EN 55024

EN 61000-3-2, EN 61000-3-3

C-Tick (AS/NZS 3548)

NEBS Level 3 Tested and Certified

CE Mark