Prepare before installing – Beckett SDC 12V User Manual

Page 3

background image

3

12Vdc SDC Burner Manual

Notice Special Requirements

If you discover damage to the burner
or controls during unpacking, notify

the carrier at once and fi le the appropriate claim.

When contacting Beckett for service
information — Please record the

burner serial number (and have available when calling or
writing). You will fi nd the serial number on the silver label
located on the left rear of the burner. See Figure 1.

Section: Prepare Before Installing

Owner’s Responsibility

Incorrect installation, adjustment, and

use of this burner could result in severe

personal injury, death, or substantial

property damage from fi re, carbon

monoxide poisoning, soot or explosion.

Contact a professional, qualifi ed service agency for the

installation, adjustment and service of your oil heating

system. This work requires technical training, trade

experience, licensing or certifi cation in some states and

the proper use of special combustion test instruments.

Please carefully read and comply with the following

instructions:

Never store or use gasoline or other fl ammable liquids
or vapors near this burner or appliance.
Never attempt to burn garbage or refuse in this
appliance.
Never attempt to light the burner/appliance by throwing
burning material into the appliance.
Never attempt to burn any fuel not specifi ed and
approved for use in this burner.
Never restrict the air inlet openings to the burner or
the combustion air ventilation openings in the room.

y

y

y

y

y

Impaired Burner Performance
and Fire Hazard.

Do NOT operate the burner beyond specifi cations

outlined in the following Table.

For applications beyond these limits, consult Beckett
Technical Service at 1-800-645-2876.
NOTE: Some packaged appliances with burners
may be agency listed as a unit to operate beyond
these limits. Consult the appliance manufacturer’s
specifi cations and agency approvals for verifi cation.

y

y

General Specifi cations

Capacity

‘F’ Head
Firing rate: 1.75 – 5.50 GPH
Input: 245,000 - 770,000 Btu/h

Fuels

USA: No. 1 or No. 2 diesel fuel or kerosene;
No.1 or No. 2 heating oil (ASTM D396)

DO NOT USE

GASOLINE, CRANKCASE OIL, OR
ANY OIL CONTAINING GASOLINE.

Electrical

Power supply: 13.5 VDC
Operating load: 25 Amps (Actual draw could

be less depending on application)
Motor: 13.5 VDC, 1/4 hp, 3450 rpm,18.75

Amps (max.), NEMA “M” fl ange, rotation

CCW when facing shaft end.
Ignition Secondary: 20KVpk 25mA

Interrupted duty OR optional continuous

duty, solid-state ignition

Pump

Outlet pressure: Note 1

Air tube

ATC code: See Table 1.

Dimensions

Height (maximum): 12-1/2 inches
Width (maximum): 14-7/8 inches
Depth (chassis only): 8-1/2 inches

Ambient
Operating
Temperature

+32° F. (0° C.) Minimum
+115° F. (+46° C.) Maximum
(See Warning on Impaired Burner Perfor-
mance and Fire Hazard.)

Note 1. See equipment manufacturer’s burner specifi cations

for recommended outlet pressure. Pressure is 100 psig unless

otherwise noted.

Prepare Before Installing