Part six – display readings and what they mean, Dc powered in battery backup operation – Kidde KN-COPP-3 (900-0099) User Manual
Page 20

" 0 "
NONE
OPERATION ON BATTERY
BACKUP,SENSING FOR CO
BATTERY IS FULLY CHARGED,
FIRST 5 MINUTES OF OPERATION
ON BACKUP BATTERY
CONNECT TO AC POWER
"0" OR CO
CONCENTRATION
DISPLAYED ONCE EVERY
60 SECONDS, FLASHING
DOT
NONE
BATTERY CONSERVE MODE,
SENSING FOR CO .
BATTERY IS FULLY CHARGED AND
AFTER 5 MINUTES OF OPERATION
ON BACKUP BATTERY
NORMAL BATTERY-ONLY OPERATION.
TO RECHARGE BATTERY, CONNECT TO
AC POWER.
"0" OR CO
CONCENTRATION
ALTERNATING WITH "Lb"
NONE
BATTERY IS PARTIALLY
DISCHARGED, FIRST 5 MINUTES
OF OPERATION ON BACKUP
BATTERY
CONNECT TO AC POWER TO FULLY
RECHARGE BATTERY
"0" OR CO
CONCENTRATION & "Lb"
DISPLAYED ONCE EVERY
60 SECONDS, FLASHING
DOT EVERY SECOND
1 CHIRP EVERY 15
SECONDS
BATTERY IS PARTIALLY
DISCHARGED AFTER 5 MINUTES
OF OPERATION ON BACKUP
BATTERY
FLASHING DOT ONCE
EVERY 60 SECONDS
1 "CHIRP" EVERY 60
SECONDS
UNIT IN TROUBLE ALARM
MODE. WILL CONTINUE FOR
APPROXIMATELY 7 HOURS.
WILL NOT DETECT CO
OPERATION ON BATTERY BACKUP
AND BATTERY IS FULLY
DISCHARGED.
NONE
NONE
UNIT IS NOT OPERATIONAL.
WILL NOT DETECT CO
BATTERY DISCONNECTED OR
MISSING
BATTERY CONSERVE MODE,
SENSING FOR CO .
CONFIRM BATTERY CONNECTION IS
FULLY SEATED AND ORIENTED
PROPERLY, CONNECT TO AC POWER
TO FULLY CHARGE BATTERY.
CONTACT KIDDE CUSTOMER SERVICE IF
CONDITION CONTINUES
18
If at any time you test the alarm and it does not perform as described, have it replaced immediately.
Part Six – Display Readings and What They Mean
DC POWERED IN BATTERY BACKUP OPERATION
Display Shows Alarm Sound Unit Status Unit Condition Recommended Action
2507-7205-00 4/6/05 17:14 Page 20