beautypg.com

Part six – display readings and what they mean, Dc powered in battery backup operation – Kidde KN-COPP-3 (900-0099) User Manual

Page 20

background image

" 0 "

NONE

OPERATION ON BATTERY

BACKUP,SENSING FOR CO

BATTERY IS FULLY CHARGED,

FIRST 5 MINUTES OF OPERATION

ON BACKUP BATTERY

CONNECT TO AC POWER

"0" OR CO

CONCENTRATION

DISPLAYED ONCE EVERY

60 SECONDS, FLASHING

DOT

NONE

BATTERY CONSERVE MODE,

SENSING FOR CO .

BATTERY IS FULLY CHARGED AND

AFTER 5 MINUTES OF OPERATION

ON BACKUP BATTERY

NORMAL BATTERY-ONLY OPERATION.

TO RECHARGE BATTERY, CONNECT TO

AC POWER.

"0" OR CO

CONCENTRATION

ALTERNATING WITH "Lb"

NONE

BATTERY IS PARTIALLY

DISCHARGED, FIRST 5 MINUTES

OF OPERATION ON BACKUP

BATTERY

CONNECT TO AC POWER TO FULLY

RECHARGE BATTERY

"0" OR CO

CONCENTRATION & "Lb"

DISPLAYED ONCE EVERY

60 SECONDS, FLASHING

DOT EVERY SECOND

1 CHIRP EVERY 15

SECONDS

BATTERY IS PARTIALLY

DISCHARGED AFTER 5 MINUTES

OF OPERATION ON BACKUP

BATTERY

FLASHING DOT ONCE

EVERY 60 SECONDS

1 "CHIRP" EVERY 60

SECONDS

UNIT IN TROUBLE ALARM

MODE. WILL CONTINUE FOR

APPROXIMATELY 7 HOURS.

WILL NOT DETECT CO

OPERATION ON BATTERY BACKUP

AND BATTERY IS FULLY

DISCHARGED.

NONE

NONE

UNIT IS NOT OPERATIONAL.

WILL NOT DETECT CO

BATTERY DISCONNECTED OR

MISSING

BATTERY CONSERVE MODE,

SENSING FOR CO .

CONFIRM BATTERY CONNECTION IS

FULLY SEATED AND ORIENTED

PROPERLY, CONNECT TO AC POWER

TO FULLY CHARGE BATTERY.

CONTACT KIDDE CUSTOMER SERVICE IF

CONDITION CONTINUES

18

If at any time you test the alarm and it does not perform as described, have it replaced immediately.

Part Six – Display Readings and What They Mean

DC POWERED IN BATTERY BACKUP OPERATION

Display Shows Alarm Sound Unit Status Unit Condition Recommended Action

2507-7205-00 4/6/05 17:14 Page 20