Peak Level Memory

When the Peak Level button is pressed and held, the display shows the
highest CO reading taken by the CO alarm since its last reset or power
up. The Peak Level display feature will display levels between 11-999
PPM. Although the Peak Level feature will display levels below 30 PPM,
these levels will not result in an alarm no matter how long the device is
exposed to these levels. The Peak Level feature is helpful in identifying if
you have had a CO reading since resetting the alarm.

Concentrations of CO between 1 and 30 PPM can often occur in nor-
mal, everyday conditions. Concentrations of CO below 30 PPM may be
an indication of a transient condition that may appear today and never
reappear. Some CO conditions may start out as low level leaks but could
develop into CO concentrations that may become harmful.

Peak Level Memory Reset

Press the Peak Level button; with the button still pressed, press the
Test/Reset button for two seconds and release. The number on the dis-
play will turn to “0”, the memory will be cleared and the alarm will
begin monitoring for CO. The Peak Level memory is also reset when the
unit loses power.

6. Model KN-COEG-3 Operating Characteristics

Operating and Alarm Characteristics

LED Display Shows

Alarm Sound

Unit Status

Recommendation

No display alternating
with “0” every 60
seconds.

None

Normal operation
after first 4 minutes
of 9 V battery
operation. Unit
monitoring for CO

Verify AC power is
restored as soon as
possible to conserve
battery.
Replace battery

Display shows
“GAS”

1/2 second
beep, 1/2
second silence,
repeating

Unit has detected gas Refer to “What to do

When the Alarm
Sounds” for Gas
(inside front cover)

Flashing dot

None

Normal battery-only
operation– unit will
show reading only if
it senses CO or gas

Plug into AC power
as soon possible to
conserve battery

“End” displayed.
Red LED flashes
every 30 seconds

Unit beeps every
30 seconds

End of unit life

Replace unit immedi-
ately. Unit will not
respond to CO or
Gas