nect up to a total of 6 remote signaling devices and/or relay modules.
• When mixing models which have battery backup (i12040, i12040A, i12060,
i12060A, i12080, i12080A, i12090A, i4618, i4618A, i5000, 1275, 1276,
1285, 1296, PE120, PI2000, PI2010, KN-COSM-IB, RF-SM-ACDC, KN-COPE-I,
KN-SMFM-I, HD135, KN-COB-IC, KN-COP-IC) with models without battery
backup, (1235, i12020, i12020A, KN-COSM-I SM120X, CO120X SL177I) be
advised that the models without battery backup will not respond during an
AC power failure.
• The maximum wire run distance between the first and last unit in an intercon-
nected system is 1000 feet.
• Figure 4 illustrates interconnection wiring. Improper connection will result in
damage to the alarm, failure to operate, or a shock hazard.
• Make certain alarms are wired to a continuous (non-switched) power line.
NOTE: Use standard UL listed household wire (as required by local codes) avail-
able at all electrical supply stores and most hardware stores.
FIGURE 4 INTERCONNECT WIRING DIAGRAM
WIRES ON ALARM HARNESS
CONNECTED TO
Black
Hot Side of AC Line
White
Neutral Side of AC Line
Red
Interconnect Lines (Red Wires) of Other
Units in the Multiple Station Set up
BATTERY INSTALLATION (models i12040A and i12080A only)
See MAINTENANCE (section 6) for battery installation.
CAUTION! IF THE BATTERY REMINDER FINGER(S) ARE NOT HELD DOWN
IN THE BATTERY COMPARTMENT BY THE BATTERY, THE BATTERY DOOR
WILL NOT CLOSE, THE AC QUICK CONNECTOR WILL NOT ATTACH TO THE
ALARM, AND THE ALARM WILL NOT ATTACH TO THE TRIM RING (SEE
SECTION 6, FIGURE 9).
FUSE OR CIRCUIT BREAKER
RED
BLACK
WHITE
BLACK
WHITE
RED
CONNECTOR
CONNECTOR
Kidde
Relay Module
SM120X
First
Alarm
Additional
Alarm
Optional
Accessory
Additional
Alarm
1220-7205-00(820-1183D-EN).qxd:_ 2010.9.3 7:04 PM Page 6