nect up to a total of 6 remote signaling devices and/or relay modules.

• When mixing models which have battery backup (i12040, i12040A, i12060,

i12060A, i12080, i12080A, i12090A, i4618, i4618A, i5000, 1275, 1276,
1285, 1296, PE120, PI2000, PI2010, KN-COSM-IB, RF-SM-ACDC, KN-COPE-I,
KN-SMFM-I, HD135, KN-COB-IC, KN-COP-IC) with models without battery
backup, (1235, i12020, i12020A, KN-COSM-I SM120X, CO120X SL177I) be
advised that the models without battery backup will not respond during an
AC power failure.

• The maximum wire run distance between the first and last unit in an intercon-

nected system is 1000 feet.

• Figure 4 illustrates interconnection wiring. Improper connection will result in

damage to the alarm, failure to operate, or a shock hazard.

• Make certain alarms are wired to a continuous (non-switched) power line.

NOTE: Use standard UL listed household wire (as required by local codes) avail-
able at all electrical supply stores and most hardware stores.

FIGURE 4 INTERCONNECT WIRING DIAGRAM

WIRES ON ALARM HARNESS

CONNECTED TO

Black

Hot Side of AC Line

White

Neutral Side of AC Line

Red

Interconnect Lines (Red Wires) of Other
Units in the Multiple Station Set up

BATTERY INSTALLATION (models i12040A and i12080A only)

See MAINTENANCE (section 6) for battery installation.

CAUTION! IF THE BATTERY REMINDER FINGER(S) ARE NOT HELD DOWN
IN THE BATTERY COMPARTMENT BY THE BATTERY, THE BATTERY DOOR
WILL NOT CLOSE, THE AC QUICK CONNECTOR WILL NOT ATTACH TO THE
ALARM, AND THE ALARM WILL NOT ATTACH TO THE TRIM RING (SEE
SECTION 6, FIGURE 9).

FUSE OR CIRCUIT BREAKER

RED

BLACK

WHITE

BLACK

WHITE

RED

CONNECTOR

CONNECTOR

Kidde

Relay Module

SM120X

First
Alarm

Additional
Alarm

Optional

Accessory

Additional
Alarm