Rane THX 22 User Manual
Page 4
Manual-2
FRONT PANEL DESCRIPTION
ቢ Graphic equalizer filter level controls. The Left and Right Channels have eleven slide controls used to set the individual
levels of the constant-Q filters. Their range is ±6 dB. The grounded center-detent design ensures each filter is off when
positioned to 0 dB.
ባ Parametric equalizer LEVEL control. Two parametric sections are included in each Channel with a ±6 dB range. This
control sets the amount of boost/cut for each parametric section. Same grounded center-detent design as the Graphic
Equalizer sections.
ቤ Parametric equalizer BANDWIDTH control. Slide control used to set the Bandwidth for this filter section. The range is
0.7-3.5 octaves.
ብ Parametric equalizer FREQUENCY control. Slide control used to determine the center Frequency for this filter section.
The range is 1 kHz-10 kHz.
ቦ POWER indicator. This LED lights any time power is supplied from the Rane model RS 1 power supply (included). To
avoid confusion a distinction is made here between electrical and political.
ቧ Overall BYPASS switch & indicator. This pushbutton switch activates the “hard-wire” BYPASS function. When engaged
(red BYPASS LED on), the INPUT connectors directly tie to the OUTPUT connectors (hard-wired). Engaging this switch
converts the THX 22 into a relatively expensive patch cord, albeit one with pretty lights. During the initial timed power-up
sequence or power loss of any sort, the THX 22 is automatically in BYPASS mode.