CHASSIS GROUNDING

The CP 62 is supplied with a rear mounted ground-lift switch. The unit is shipped with this switch in the “grounded”

position, tying circuit ground to chassis ground. If after hooking up your system it exhibits excessive hum or buzzing, there
is an incompatibility in the grounding configuration between units somewhere. Your mission, should you accept it, is to
discover how your particular system wants to be grounded. Here are some things to try:

1. Try combinations of lifting grounds on units that are supplied with ground lift switches or links.
2. Verify that all chassis are tied to a good earth ground, (i.e., through the line cord grounding pin or grounded amplifier

chassis.) Do not depend on the painted rack screws and rails to ground the chassis.

3. The CP 62 does not ground the chassis through the line cord. Make sure that these units are grounded either to another

chassis which is earth grounded, or directly to the grounding screw on an AC outlet cover by means of a wire connected to a
screw on the chassis with a star washer to guarantee proper contact.

Please refer to RaneNote 110, “Sound System Interconnection” included in this manual for further information.