beautypg.com

Rane CP 52 1997 version User Manual

Page 3

background image

Manual-3

CP 52 - REAR PANEL

Chassis Ground Screw provides a convenient earth (technical) ground connection point. The CP 52 does not ground the

chassis through the power cord. It is important that the unit be grounded.

POWER jack accepts the cable from a Rane RS 1 remote power supply (included) or an optional Rane RAP 10 power

supply. This is not a telephone jack. Use of a supply not approved by Rane may damage the unit and void the warranty.

ZONE REMOTE Port provides the wiring interface for the optional ZR 1 wired remote. The ZR 1 remote provides remote

control of Zone Level and Zone Program Select functions. Refer to page Manual-5 for details.

ZONE OUTPUT Port features a balanced cross-coupled line driver with a Euroblock connector. These Left and Right

Outputs may be wired balanced or unbalanced.

MONO switch, when pressed in, sums the left and right signals to provide a mono Zone signal available at both Left and

Right Outputs.

ZONE EXPAND Port features a balanced cross-coupled line driver with a Euroblock connector. This mono Output may be

wired balanced or unbalanced.

ZONE EXPAND switch assigns PAGE-only, PROGRAM-only or full ZONE (both) as the source for the Expand Output.

ZONE EXPAND LEVEL trim adjusts the signal level delivered to the ZONE EXPAND OUTPUT.

PRIORITY RELEASE TIME control sets the delay time from last detected signal to release of automatic priority over-

ride. The range of control is 5 seconds (ccw) to 20 seconds (cw).

PRIORITY OFF/ON switch allows disabling the automatic priority override function when in the OFF position.

PRIORITY DETECT THRESHOLD control allows adjusting the threshold from -

(signal on) to -35 dBu (typ). The

factory setting is -50 dBu.

ቮ Four PROGRAM INPUTS are provided. Three are non-priority Inputs. The fourth is a Program PRIORITY Input. When

signal is detected at this Input, it is automatically selected as the Program Input source regardless of the front panel PRO-
GRAM SELECT setting.

PAGE LEVEL TRACKS ZONE LEVEL switch, when ON, forces the Paging level to track the Zone level. When OFF,

Paging level and Zone level are independent.

HIGH/LOW CUT FILTER switch, when IN, limits the bandwidth of the Paging Input from 100 Hz to 7 kHz, improving

intelligibility in some installations. The Paging detector is always bandlimited to 100 Hz to 7 kHz.

PHANTOM POWER switch, when ON, enables +15 volt Phantom Power to the PAGING INPUT Euroblock. If the front

panel LINE switch is selected, Phantom Power is defeated.

PAGING INPUT Euroblock connector may be wired balanced or unbalanced.