Wilbur Curtis EXPR User Manual
Page 4

4
Program Menus
Manual Dispense (Factory Default)
Press or ► to go to Manual Dispense Select.
Press to go to Manual Dispense Select Station.
Choose the station and press, the display will read Saving Complete! To select another station for manual dispense, press to go
to Manual Dispense Select Station or press ► to continue to the next menu.
Dispense By Time
The next screen is Dispense By Time ◄ Select ►.
Before making this adjustment and to avoid guessing the time, run a stop watch on the time it takes to fill a cup in the
Manual Dispense mode. Use the timed results to determine your Dispense By Time setting.
Press and all station indicator lights will flash. Select a station to program by pressing the PUSH button on your chosen sta-
tion. Screen will show the current setting (from 0.0 to 30.0 seconds, in ½ second increments). Press to ► increase the time or ◄
to decrease. To set, press and you will exit back to Dispense by Time screen. Continue with additional selections or press ► to
continue to the next menu.
Temperature (Factory set at 190°F)
Press and screen will show Tank Temperature. Temperature is programmable from 170°F to 204°F in 2-degree increments.
Press ◄ or ► to go up or down in degrees. Select desired temperature and then to set. Press ► to continue to the next
menu.
Powder % Ratio
Press and the screen will display Powder Ratio Select Station. This is shown as A, B, C, D and E, corresponding to canisters,
arranged left to right (when facing the machine), starting with A. Press desired station. Powder ratio for each canister flavor is pro-
grammable from 0% to 100%, in 5% increments.
Press ◄ or ► to increase or decrease ratio and then press to set. Press ► to continue to the next canister. After E the screen
returns to Powder Ratio. Press ► to continue to the next menu.
Service Call (Phone number)
Press to display number and press change number or ► to move places and EX to exit when complete This number will be
displayed during a Heating system SENSOR ERROR or a WATER ERROR. Press ► to continue to the next menu.
Banner Name
Press to display letters, press to change letters or ► to move places and EX to exit when complete.
This feature allows up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Ban-
ner Name. If programmed, Banner Name is displayed every 5 sec. on and off. Press ► to continue to the next menu.
Exit
Press to select, exits program mode and returns unit to operation.