Troubleshooting guide, Dos and don’ts – Wilbur Curtis TCC3 User Manual
Page 10
10
SYMPTOM
POSSIBLE CAUSE
SOLUTION
TROUBLESHOOTING GUIDE
Product flowing from the faucet
is too foamy or bubbly.
1. Reconnect tubing and tighten
clamps.
2. Make sure the barbed end of
the QCD fitting is pushed in
on the hose and the clamp is
tight.
3. Turn the BIB so the fitting
faces upward and open the
faucet until all the bubbles
are released.
4. Replace the worn O-ring or
install a new QCD.
DOs and DON’Ts
INSTALLATION
1. Do connect dispenser to a filtered waterline.
2. Do flush filters before connecting to dispenser.
3. Do sample finished drink before making ad-
justments.
4. Do make very slight drink adjustments then
sample.
5. Don’t forget to flush filters before installation.
6. Don’t make any pressure regulator adjust-
ments on dispenser (Do NOT attempt to
adjust the regulator. If a regulator adjustment
is required call CURTIS CARE).
7. Don’t forget to get sample approval from cus-
tomer.
OPERATION
1. Do fully activate faucet handle when dispens-
ing drinks.
2. Do clean & sanitize dispensing assembly
monthly.
3. Do keep dispenser primed with concentrate at
all times.
4. Do reload immediately when out of concen-
trate.
5. Do flush and clean lines regularly.
6. Don’t forget to clean & sanitize faucet seat cup
7. Do follow all cleaning and sanitizing proce-
dures. Remove and store tea concentrate if
dispenser will not be used for an extended
period of time (more than two days).
1. The clamps at the check
valve may not be tight.
2. The clamp on the QCD
connector may be loose.
3. Tea concentrate product
may have air in the BIB.
4. The O-ring on the QCD is
worn out.