Troubleshooting guide, Dos and don’ts – Wilbur Curtis TCC3 User Manual

Page 10

background image

10

SYMPTOM

POSSIBLE CAUSE

SOLUTION

TROUBLESHOOTING GUIDE

Product flowing from the faucet

is too foamy or bubbly.

1. Reconnect tubing and tighten

clamps.

2. Make sure the barbed end of

the QCD fitting is pushed in

on the hose and the clamp is

tight.

3. Turn the BIB so the fitting

faces upward and open the

faucet until all the bubbles

are released.

4. Replace the worn O-ring or

install a new QCD.

DOs and DON’Ts

INSTALLATION
1. Do connect dispenser to a filtered waterline.
2. Do flush filters before connecting to dispenser.
3. Do sample finished drink before making ad-

justments.

4. Do make very slight drink adjustments then

sample.

5. Don’t forget to flush filters before installation.
6. Don’t make any pressure regulator adjust-

ments on dispenser (Do NOT attempt to

adjust the regulator. If a regulator adjustment

is required call CURTIS CARE).

7. Don’t forget to get sample approval from cus-

tomer.

OPERATION
1. Do fully activate faucet handle when dispens-

ing drinks.

2. Do clean & sanitize dispensing assembly

monthly.

3. Do keep dispenser primed with concentrate at

all times.

4. Do reload immediately when out of concen-

trate.

5. Do flush and clean lines regularly.
6. Don’t forget to clean & sanitize faucet seat cup
7. Do follow all cleaning and sanitizing proce-

dures. Remove and store tea concentrate if

dispenser will not be used for an extended

period of time (more than two days).

1. The clamps at the check

valve may not be tight.

2. The clamp on the QCD

connector may be loose.

3. Tea concentrate product

may have air in the BIB.

4. The O-ring on the QCD is

worn out.